7. Disconnect the battery wires from the battery.
8. Install the replacement battery by connecting the red wire to the positive (+) terminal of the battery and
connecting the black wire to the negative (-) terminal of the battery.
9. Slide the battery back into the compartment.
0. Replace the outlet cover and the 6 retaining screws.
. Recharge the unit for 4 – 8 hours to ensure the UPS performs expected runtime.
REMINDER:
Batteries are consider
HAZARDOUS WASTE
and must be disposed of properly. Contact your local
government for more information about proper disposal and recycling of batteries.
DEFINITIONS FOR ILLUMINATED LED INDICATORS
Power ON
Wiring Fault
CONDITION
On
Off
Normal
Off
On/Off
Utility Failure-
the UPS is providing power to battery
power-supplied outlets from its battery.
Off
On/Off
Utility Failure-
The UPS is providing battery power.
Rapid beeps indicate the unit will run out of power
shortly.
Off
Off
System Overload-
Occurs when connected equipment
exceeds the rating of unit. Turn the UPS off, unplug at
least one piece of equipment, wait 0 seconds, reset
the circuit breaker and turn the unit on.
Off
On/Off
Battery Overload-
Occurs when connected equipment
exceeds the rating of battery outlets of the unit. Turn
the UPS off, unplug at least one piece of equipment
from battery outlets, wait 0 seconds, reset the circuit
breaker and turn the unit on.
On/Off
On
Electrical Wiring Fault-
This
indicates a wiring
problem with the AC outlet
such as bad ground,
miss ground, or reversed wiring. User is advised to
disconnect all electrical equipment from the outlet and
have an electrician check the outlet to insure proper
wiring.
Model: 25654
425VA/230W UPS Backup System
7