OPERATIONAL CHARACTERISTICS
6.1
Absolute Maximum Ratings
Parameter
Min
Typ
Max
Unit
Main power supply voltage
6
12
20
V
NOTE: Stresses beyond Absolute Maximum Ratings may cause permanent damage to the
device.
6.2
Recommended Operating Conditions
Parameter
Condition
Min
Typ
Max
Unit
Main power supply voltage
12 Volt is
not
used by PCI or P19
7.5
12
17
V
Main power supply voltage
12 Volt is used by PCI or P19
See Note
12
See Note
V
NOTE: The allowed main power supply voltage range is determined by the allowed range of the
PCI device using 12V through connector P3, the device drawing it’s power from P19
and the range of SB-A510 when no devices use 12V on SB-A510.
6.3
DC Electrical Characteristics
DC electrical characteristics of SB-A510 are derived from the characteristics of the CM-A510. Please
refer to the “CM-A510 reference guide”.
6.4
Power Consumption
To be added in a future revision of this document.