5-8
Setting the Clock [Long Entry]
Key-up and send [*21] followed by the hours, minutes, day of week, day of month, month of year and
year. Un-key and the voice will say "CLOCK SET OK." Example: 2:55 PM Monday January 25th. All
entries must be double digit, except the day of week.
Setting the Clock [Short Entry]
Key-up and send [*22] followed by the hours, and minutes. Un-key and the voice will say "CLOCK SET
OK." Example: 2:55 PM Monday.
Program Forced Entry Command [*29]
DTMF commands are entered when the port goes inactive. To force a DTMF command when the port is
active, end the command with a [D]. This key can be changed with the [*29X] programming
command. To change this key to [#], key-up and send [*29#]. Un-key, the voice will say: “CONTROL
OK.” Select [*], [#], [A], [B], [C], or [D]. To read the command, key-up and send [*29].
Send Voice Message [*3001]-[*3020]
Key-up and send [*3001]. Un-key and the voice synthesizer will say the ID.
Program Voice Message [*3101]-[*3120]
Key-up and send [*31XX] followed by the message number and three digit numbers that represent the
words required to construct the ID. Memory space is provided for 15 entries. Refer to the Voice
Vocabulary Word List. Example: Load Repeater ID with "W4XYZ Repeater”.
Day of Week (1=SUN 7=SAT)
Minutes (0-59) Day of Month (01-31)
Hours (0-23) Month of Year (01-12)
Year
Programming Command *21 14 55 2 25 01 03
Hours (0-23) Minutes (0-59)
Programming Command *22 14 55
Message Number W 4 X Y Z Repeater
Programming Command *31 01 890 004 920 930 950 746