- 5 -
•
The 1st and 2nd zones, beside their regular connection points, also have
a joint connection point for a zone valve/pump (Z1-2). If any of the 1st two
thermostats (T1 and/or T2) switches on, then beside the 230 V AC voltage
appearing at Z1 and/or Z2, 230 V AC voltage appears on Z1-2 too
, and the
zone valves/pumps connected to these connection points open/start. This
Z1-2
connection point is suitable to control the zone valves/pumps in such rooms
(e.g. the hall or the bathroom), which do not have a separate thermostat, do not
need heating at all times but need heating when any of the 1st two zones heat.
•
The 3rd and 4th zones, beside their regular connection points, also have
a joint connection point for a zone valve/pump (Z3-4). If any of the 2nd two
thermostats (T3 and/or T4) switches on, then beside the 230 V AC voltage
appearing at Z3 and/or Z4, 230 V AC voltage appears on Z3-4 too
, and the
zone valves/pumps connected to these connection points open/start. This
Z3-4
connection point is suitable to control the zone valves/pumps in such rooms
(e.g. the hall or the bathroom), which do not have a separate thermostat, do not
need heating at all times but need heating when any of the 2nd two zones heat.
•
Moreover, the four heating zones also have a joint connection point
for a zone valve/pump (Z1-4). If any of the four thermostats (T1, T2, T3
and/or T4) switches on, then beside the 230 V AC voltage appearing
at Z1, Z2, Z3 and/or Z4, 230 V AC voltage appears on Z1-4 too
, and the
pump connected to output
Z1-4
also starts. This
Z1-4
connection point is
suitable to control the heating in such rooms (e.g. the hall or the bathroom),
which do not have a separate thermostat, do not need heating at all times but
need heating when any of the four zones heat. This connection point is also
suitable for controlling a central circulating pump, which starts whenever any
of the heating zones starts.
•
There are some zone valve actuators that need a fix phase, a switched
phase and a neutral connection to operate. The connection points of the fix
phase are next to the (
POWER INPUT)
indicated by the
FL FL
sign. The
connections of the fix phase are only operating when the power switch is
turned on. Due to the lack of space there is only two connection points. By
joining the fix phases four actuators can be operated.
•
The 15 A fuse on the right side of the power switch protects the components
of the zone controller from electrical overload. In case of overloading the
fuse cuts off the electric circuit, protecting the componets. If the fuse has cut
off the circuit, check the appliances connected to the zone controller before