background image

MENU - ALARM (continued) 

TP4MD/CD / TP10MD/CD / TP16MD/CD 

11

 

E

N

G

L

IS

H

 

DISPLAY 

When the alarm is detected, the camera with the last 
activated  alarm  can  be  switched  into  the  full  screen 
mode or the alarm cameras on the main or spot chan-
nel can cycle according to the prepared period. 
 

 

 

RELAY CONTACTS 

Controlling an alarm output is displayed in the follow-
ing menu. 
 

 

 

Normally  open/closed 

–  this  function  defines  the 

situation of the relay without alarm. 

Follow record 

– if this function is selected, the relay 

is  active  during  the  recording,  functions  below  than 
have no meaning. 

No reaction to alarm 

– no reaction to alarm inputs. 

Follow input 

– active during the alarm lasting on any 

of the inputs. 

Switch on XX seconds 

– active for the time from 1 to 

99 seconds since the last alarm activation. 

No reaction to camera fail 

– no reaction to the video 

signal lost. 

Switch on XX seconds 

– active for the time from 1 to 

99 seconds since the camera signal fails. 

No  reaction  to  activity  detector

  –  activity  detector 

does not influence alarm output. 

Switch on XX seconds 

– active for the time from 1 to 

99 seconds since the last activity detection. 
 

SPEAKER  

This  menu  controls  the  acoustic  signalling  of  alarm. 
Meaning  of  corresponding  lines  is  the  same  as  in 
menu 

Relay contacts

 (see page 11). 

 

 

 
 

Summary of Contents for TP10CD

Page 1: ...ENGLISH BLACK WHITE AND COLOUR MULTIPLEXERS Installation and user manual TP4MD TP10MD TP16MD TP4CD TP10CD TP16CD ...

Page 2: ......

Page 3: ...CAN RS 485 RS 232 INTERFACE 4 EXTERNAL KEYBOARD 4 MULTIPLEXER NETWORKING 4 MULTIPLEXER CONTROLLING 5 CAMERA DISPLAYING LIVE 5 PLAYBACK PLAY 5 DIGITAL ZOOM ZOOM 5 PICTURE RECORDING REC 5 ANALOGUE CHANNEL CONTROLL SEQ 5 DISPLAYING VCR INPUT VCR 5 SELECT VIEW VIEW 5 TELEMETRY CONTROLLING 5 FREEZE PICTURE HOLD 6 LOAD MACRO MACRO 6 ALARM STATUS ALARM 6 LIST OF EVENTS 6 MENU 7 MAIN MENU 7 VIDEORECORDER ...

Page 4: ...tching The spot channel is used even for manual controlling from the main panel o 4 10 or 16 video inputs o main and spot output o VCR input and output o automatic TV standard detection from connected cameras o 864 samples per a TV line CCIR PAL 856 EIA NTSC o 576 active TV lines CCIR PAL 480 EIA NTSC o 256 grey scale 16 million colours o RS 485 and CAN interface for telemetry control ling of pan ...

Page 5: ...tions 16 IN1 IN16 Video inputs for cameras 1 16 The video inputs are automatically terminated if the corresponding video output is left unconnected If a device is connected to video out make sure that it is properly terminated 17 VCR IN Use this video input for connecting from VCR 18 SPOT Video output to spot monitor 19 OUT1 OUT16 Video outputs for cameras 1 16 20 VCR OUT Video output to VCR 21 MA...

Page 6: ...cted to the CAN bus You can connect several external keyboards to CAN bus and control different or the same devices During controlling of one device by several keyboards you are able to operate controlled device by another key board five seconds after the last command of the pre vious keyboard it is not possible to control one device from two keyboards at the same time MULTIPLEXERS NETWORKING Usin...

Page 7: ... channel is switched on by pressing the button SEQ The buttons 1 to 16 are used for displaying a corresponding camera by press ing the button AUTO it is switched the automatic switching sequence on or off Set up sequential switching parameters using the menu Sequence Cameras in sequence and Time multiplier see page 8 and 9 By another pressing the button SEQ the mul tiplexer switches back into the ...

Page 8: ...er leaving the cameras menu and pressing the PRESET button you return back to the pan tilt and lens controlling mode After that the PRESET disa pears from the status line FREEZE PICTURE HOLD During LIVE and PLAY modes pressing the button HOLD freezes the main channel monitor view The picture starts to move again by other pressing of this LOAD MACRO MACRO TP multiplexers enable to define so called ...

Page 9: ...nction it is important to ensure that the VCR and multiplexer work in the same mode You can also define the type of the con nection between the VCR and the multiplexer with the help of AUX input VCR TYPE Set up your VCR type here If your VCR type is not mentioned here use an analogous type or choose a user defined VCR and set up the working VCR modes in the menu User defined VCR see page 7 VCR MOD...

Page 10: ...CR and the multiplexer If the operator switches the recording speed on the VCR or the recording speed is changed by the influence of the alarm signal on the VCR the multiplexer changes its recording speed automatically Start record if the AUX input activity is detected multiplexer starts the recording automatically MENU CAMERA Set up camera parameters of recording displaying activity detection seq...

Page 11: ...rameter TIME MULTIPLIER The time of the displaying of particular cameras can be quite lengthened or shortened and the proportion of displaying particular steps cameras still lasts It is important to note that the time of displaying one step after the change will still stay in interval of 1 to 255 seconds There is an illustrated example in the table how the switching time changes according to the p...

Page 12: ...m inputs marking the line the alarm inputs will influence recording Activity detector if you mark this line the activity detector will influence recording Alarmed cameras only only the cameras with the alarm detection will be recorded during the alarm las ting The source of the alarm can be either from the alarm inputs or from the activity detector Selected alarmed cameras only only the cameras wi...

Page 13: ...functions below than have no meaning No reaction to alarm no reaction to alarm inputs Follow input active during the alarm lasting on any of the inputs Switch on XX seconds active for the time from 1 to 99 seconds since the last alarm activation No reaction to camera fail no reaction to the video signal lost Switch on XX seconds active for the time from 1 to 99 seconds since the camera signal fail...

Page 14: ...ctor will explore the image changes can be defined with the help of this matrix 18 x 9 of light sensitivity elements for every camera The transparent squares represent active fields There are described controlling buttons for editing the light sensitivity matrix here 1 sets one active matrix field 2 clears one field 3 sets the whole line 4 clears the whole line WALK TEST The walk test is used for ...

Page 15: ...ded cameras will be changed after the macro is launched Select cameras by opening this submenu you can choose your own set of the cameras for recording Activity detector by marking this line the cameras for activity detection will be changed after the macro is launched Select cameras your own set of the cameras for activity detection Sensitivity of the detector by marking this line the sensitivity...

Page 16: ...ist of events which corresponds to previous setting in this menu CLEAR LIST You can clear the list of events in this menu by pres sing the button 1 MENU SYSTEM In this menu you can set up such parameters which correspond to the functions of multiplexers as the password the data and time setting interlace correc tion telemetry characteristics and the language choice PASSWORD The user can control th...

Page 17: ... the multiplexer and its format of displaying on the monitor If you choose some time and date item time will stop and will not start since this menu is finished TIME CORRECTION You can correct the multiplexer internal clock devia tions by setting the value of seconds added or taken off per a day For example If the clock of multiplexers delays 2 5 seconds a day increase the value of the correction ...

Page 18: ...ess can be set up here Parameters setup parameters for selected protocol The following menus control the function of user out puts AUX1 AUX2 see Telemetry controlling on page 8 Change output by pressing one of the buttons AUX1 2 the state of user output will be changed Follow key The user output is switched on while holding the button AUX ENABLE EXTERNAL KEYBOARD marking this line you enable multi...

Page 19: ...mination at the end of the line by the connected device or must be left unconnected Cameras on divided screen are slightly shaking Interlace correction is switched off oSet up the interlace correction of live picture in menu SYSTEM DISPLAY page 16 The shaking stops with result of slower displaying At colour multiplexer displayed have incorrect colours Improper setting of camera parameters oCheck t...

Page 20: ...of the alarm inputs is defective oCheck the connection of the alarm inputs page 3 The device reacts to alarm inputs incorrectly The set up of alarm inputs polarity is incorrect oCheck the polarity of alarm inputs in menu ALARM INPUTS page 10 The alarm output relay does not react properly The polarity of alarm is set up incorrectly oSet up the normal state of alarm output in menu RELAY CONTACTS pag...

Page 21: ...pin female connector AUX INPUT Loop connection input ground GND Activity programmable Maximum alarm loop impedance 1 kW ALARM OUTPUT Number 1 potentialless contacts of low voltage relay Maximum switching voltage 40 V Maximum switching current 0 5 A RS 485 INTERFACE Baud rate depend on protocol Maximum length 1000 m Terminators 120 W at both ends CAN INTERFACE Baud rate 50 kBs Maximum length bus st...

Reviews: