TECHNICAL SPECIFICATION
TP4MD/CD / TP10MD/CD / TP16MD/CD
19
E
N
G
L
IS
H
PICTURE PARAMETERS
TV standard:
PAL (CCIR) / NTSC (EIA)
Number of the active TV lines:
576 / 480
Samples per TV line:
864 / 856
Grey scale (black and white multiplexers):
256
Number of colours (colour multiplexers):
16 million
VIDEO INPUTS
Number:
4+1, 10+1 or 16+1 (composite)
Amplitude:
0,75 - 1,5V p-p
Input impedance:
75
W
(high if a connector is plugged in to video output)
Connectors:
BNC (composite)
VIDEO OUTPUTS
Number:
3 independent (composite), 1 independent (S-VIDEO)
Standard:
1 V p-p
load of 75
W
Connectors:
BNC (composite), MINI DIN 4 (S-VIDEO)
ALARM INPUTS
Number:
4, 10 or 16
Loop connection:
input – ground (GND)
Activity:
programmable
Maximum alarm loop impedance:
1 k
W
Connector:
D-SUB 37-pin female connector
AUX INPUT
Loop connection:
input – ground (GND)
Activity:
programmable
Maximum alarm loop impedance:
1 k
W
ALARM OUTPUT
Number:
1 potentialless (contacts of low voltage relay)
Maximum switching voltage:
40 V
Maximum switching current:
0.5 A
RS 485 INTERFACE
Baud rate:
depend on protocol
Maximum length:
1000 m
Terminators:
120
W
at both ends
CAN INTERFACE
Baud rate:
50 kBs
Maximum length: bus/ stubs/ cumulative stubs
1000 m / 60 m / 300 m
Terminators:
120
W
at both ends
Cable for bus length 0 – 40 m:
0.25mm
2
- 0.34mm
2
(AWG23, AWG22)
Cable for bus length 40 – 600 m:
0.34mm
2
- 0.6mm
2
(AWG20)
Cable for bus length 600 – 1000 m:
0.75mm
2
- 0.8mm
2
(AWG18)
TEMPERATURE CONDITIONS
Range of operating temperatures:
0 – 40
°
C
Humidity:
max. 85 %
POWER SUPPLY
Input voltage:
12 VDC
Power consumption:
max. 7 W
Connector:
concentric 5.5 × 2.1 mm
MECHANICAL PARAMETERS
Dimensions:
436(W) × 44.5(H) × 230(D) mm
Weight:
3,3 kg
ACCESSORIES
Alarm connector D-SUB male + cover:
1 piece
Summary of Contents for TP10CD
Page 2: ......