background image

MULTIPLEXER CONTROLLING 

 TP4MD/CD / TP10MD/CD / TP16MD/CD 

5

 

E

N

G

L

IS

H

 

CAMERAS DISPLAYING – LIVE 

The  camera  displaying  is  an  implicit  mode,  which  is 
started after the device has been switched on. Came-
ras are displayed according to the last chosen view. 
Set  up  camera  to  the  first  position  by  pressing  the 
corresponding  button  1  to  16;  the  following  cameras 
are  arranged  automatically.  If the camera was at the 
first position, it will be displayed at full screen. The TP 
multiplexers omit the displaying of the disabled cam-
eras, that provides the better compatibility of display-
ing without empty frames among the cameras. 
The  first  camera  has  the  privilege  of  the  zooming 
function  (ZOOM  -  PLAY  mode  only)  and  telemetry 
controlling. 
Pressing  the  button  AUTO  it  switches  the  automatic 
switching  sequence  on  or  off.  Set  up  the  sequence 
parameters  using  the  menu 

Sequence,  Displayed 

cameras 

and 

Time multiplier (

see page 8 and 9). 

 

PLAYBACK RECORDING - PLAY 

The  playback  of  the  coded  record  from  the  VCR  is 
switched ON by pressing the PLAY button. The cam-
eras are displayed on the screen of the main channel 
according to the topical view in this mode. 
Pressing the button 1 to 16 set up the particular cam-
era to the first view position; the following cameras are 
arranged  automatically.  The  function  of  zooming 
(ZOOM) is always available only for the first camera. 
By another pressing the button PLAY, the multiplexer 
switches into the LIVE mode. 

 

DIGITAL ZOOM - ZOOM 

Digital  picture  zoom  can  be  switched  on  only  in  the 
PLAY  mode  by  pressing  the  button  ZOOM+.  When 
you are using the zoom function, only the centre of the 
whole picture is displayed on the monitor screen. The 
picture  can  be  moved  using  the  direction  arrows. 
When the zoom is on, the title ZOOM is displayed on 
the monitor status line. The zoom can be set up only 
on the main channel. The digital zoom will be turned 
off by pressing the button ZOOM- or ZOOM+. 

 

PICTURE RECORDING - REC 

The recording of the coded images is switched on by 
pressing  the  button  REC  and  it  is  indicated  by  red 
point  in  the  status  line. Recording uses its own inde-
pendent  channel  without  affecting  the  main  channel. 
Another pressing the REC button stops recording. 

 

ANALOGUE CHANNEL CONTROLLING - SEQ 

Controlling a spot analogue channel is switched on by 
pressing  the  button  SEQ.  The  buttons  1  to  16  are 
used for displaying a corresponding camera, by press-
ing  the  button  AUTO  it  is  switched  the  automatic 
switching  sequence  on  or  off.  Set  up  sequential 
switching  parameters  using  the  menu 

Sequence, 

Cameras in sequence 

and 

Time multiplier (

see page 8 

and 9). By another pressing the button SEQ, the mul-
tiplexer switches back into the controlling of the main 
channel. 

 

DISPLAYING VCR INPUT - VCR 

When  playback  does  not  work  as  expected,  it  is 
probably  caused  by  missing  or  improper  signal  at 
VCR IN input. 
Press and hold the PLAY key for at least 2 seconds to 
display signal from VCR IN to the monitor controlled at 
the  moment.  If  you  control  LIVE  or  PLAY  mode,  the 
picture is processed digitally (as real playback), when 
you control analogue channel, the signal is displayed 
as it is to the analogue output. 
Releasing the PLAY key returns the multiplexer to its 
previous mode. 

 

SELECT VIEW – VIEW 

The  view  on  the  main  monitor  can  be  selected  by 
pressing the VIEW button. On the monitor screen the 
following  menu  will  be  displayed  and  than  the  de-
manded view can be chosen by pressing the button 1 
to 12. Only the first 6 displayed possibilities are avail-
able for 4 channel multiplexers and only the first 10 for 
10 channel multiplexers. 

 

 

 

TELEMETRY CONTROLLING  

TP  multiplexers  offer  remote  controlling  of  cameras 
using  the  RS  485  and  the  CAN  interface.  If  a  split 
screen  is  being  displayed,  you  can  control  the  first 
camera of the view (left top corner of the view or the 
centre at the view no. 11). Only cameras with teleme-
try  receiver  address  set  up  can  be  controlled.  This 
address  is  set  up  in  the  menu 

Telemetry  addresses 

(

see page 9). 

 

PAN/TILT unit and lens controlling: 

PAN/TILT  camera  heads  are  controlled  using  the  di-
rection  buttons.  The  lens  is  controlled  using  the  but-
tons ZOOM +/-, FOCUS +/-, IRIS +/-. Automatic focus 
or  iris  is  turn  on  by  pressing  the  buttons  PRESET, 
AUTO,  FOCUS+  or  IRIS+,  if  camera  support  this. 
Automatic function is turn off by start of manual con-
troll. 

 

User AUX outputs controlling: 

Multiplexer  can  control  2  user  outputs  (AUX1  and 
AUX2)  of  the  telemetry  receiver.  The  user  outputs 
controlling  is  possible  with  the  use  of  the  buttons 
PRESET  (the  button  starts  flashing)  and  one  of  the 
buttons  ZOOM.  Allocation  of  the  individual  user  out-
puts AUX to the buttons is as following: 

AUX1 – ZOOM+ 
AUX2 – ZOOM- 

The  output  function  can be set up in the menu 

Tele-

metry (

see page 16). 

Summary of Contents for TP10CD

Page 1: ...ENGLISH BLACK WHITE AND COLOUR MULTIPLEXERS Installation and user manual TP4MD TP10MD TP16MD TP4CD TP10CD TP16CD ...

Page 2: ......

Page 3: ...CAN RS 485 RS 232 INTERFACE 4 EXTERNAL KEYBOARD 4 MULTIPLEXER NETWORKING 4 MULTIPLEXER CONTROLLING 5 CAMERA DISPLAYING LIVE 5 PLAYBACK PLAY 5 DIGITAL ZOOM ZOOM 5 PICTURE RECORDING REC 5 ANALOGUE CHANNEL CONTROLL SEQ 5 DISPLAYING VCR INPUT VCR 5 SELECT VIEW VIEW 5 TELEMETRY CONTROLLING 5 FREEZE PICTURE HOLD 6 LOAD MACRO MACRO 6 ALARM STATUS ALARM 6 LIST OF EVENTS 6 MENU 7 MAIN MENU 7 VIDEORECORDER ...

Page 4: ...tching The spot channel is used even for manual controlling from the main panel o 4 10 or 16 video inputs o main and spot output o VCR input and output o automatic TV standard detection from connected cameras o 864 samples per a TV line CCIR PAL 856 EIA NTSC o 576 active TV lines CCIR PAL 480 EIA NTSC o 256 grey scale 16 million colours o RS 485 and CAN interface for telemetry control ling of pan ...

Page 5: ...tions 16 IN1 IN16 Video inputs for cameras 1 16 The video inputs are automatically terminated if the corresponding video output is left unconnected If a device is connected to video out make sure that it is properly terminated 17 VCR IN Use this video input for connecting from VCR 18 SPOT Video output to spot monitor 19 OUT1 OUT16 Video outputs for cameras 1 16 20 VCR OUT Video output to VCR 21 MA...

Page 6: ...cted to the CAN bus You can connect several external keyboards to CAN bus and control different or the same devices During controlling of one device by several keyboards you are able to operate controlled device by another key board five seconds after the last command of the pre vious keyboard it is not possible to control one device from two keyboards at the same time MULTIPLEXERS NETWORKING Usin...

Page 7: ... channel is switched on by pressing the button SEQ The buttons 1 to 16 are used for displaying a corresponding camera by press ing the button AUTO it is switched the automatic switching sequence on or off Set up sequential switching parameters using the menu Sequence Cameras in sequence and Time multiplier see page 8 and 9 By another pressing the button SEQ the mul tiplexer switches back into the ...

Page 8: ...er leaving the cameras menu and pressing the PRESET button you return back to the pan tilt and lens controlling mode After that the PRESET disa pears from the status line FREEZE PICTURE HOLD During LIVE and PLAY modes pressing the button HOLD freezes the main channel monitor view The picture starts to move again by other pressing of this LOAD MACRO MACRO TP multiplexers enable to define so called ...

Page 9: ...nction it is important to ensure that the VCR and multiplexer work in the same mode You can also define the type of the con nection between the VCR and the multiplexer with the help of AUX input VCR TYPE Set up your VCR type here If your VCR type is not mentioned here use an analogous type or choose a user defined VCR and set up the working VCR modes in the menu User defined VCR see page 7 VCR MOD...

Page 10: ...CR and the multiplexer If the operator switches the recording speed on the VCR or the recording speed is changed by the influence of the alarm signal on the VCR the multiplexer changes its recording speed automatically Start record if the AUX input activity is detected multiplexer starts the recording automatically MENU CAMERA Set up camera parameters of recording displaying activity detection seq...

Page 11: ...rameter TIME MULTIPLIER The time of the displaying of particular cameras can be quite lengthened or shortened and the proportion of displaying particular steps cameras still lasts It is important to note that the time of displaying one step after the change will still stay in interval of 1 to 255 seconds There is an illustrated example in the table how the switching time changes according to the p...

Page 12: ...m inputs marking the line the alarm inputs will influence recording Activity detector if you mark this line the activity detector will influence recording Alarmed cameras only only the cameras with the alarm detection will be recorded during the alarm las ting The source of the alarm can be either from the alarm inputs or from the activity detector Selected alarmed cameras only only the cameras wi...

Page 13: ...functions below than have no meaning No reaction to alarm no reaction to alarm inputs Follow input active during the alarm lasting on any of the inputs Switch on XX seconds active for the time from 1 to 99 seconds since the last alarm activation No reaction to camera fail no reaction to the video signal lost Switch on XX seconds active for the time from 1 to 99 seconds since the camera signal fail...

Page 14: ...ctor will explore the image changes can be defined with the help of this matrix 18 x 9 of light sensitivity elements for every camera The transparent squares represent active fields There are described controlling buttons for editing the light sensitivity matrix here 1 sets one active matrix field 2 clears one field 3 sets the whole line 4 clears the whole line WALK TEST The walk test is used for ...

Page 15: ...ded cameras will be changed after the macro is launched Select cameras by opening this submenu you can choose your own set of the cameras for recording Activity detector by marking this line the cameras for activity detection will be changed after the macro is launched Select cameras your own set of the cameras for activity detection Sensitivity of the detector by marking this line the sensitivity...

Page 16: ...ist of events which corresponds to previous setting in this menu CLEAR LIST You can clear the list of events in this menu by pres sing the button 1 MENU SYSTEM In this menu you can set up such parameters which correspond to the functions of multiplexers as the password the data and time setting interlace correc tion telemetry characteristics and the language choice PASSWORD The user can control th...

Page 17: ... the multiplexer and its format of displaying on the monitor If you choose some time and date item time will stop and will not start since this menu is finished TIME CORRECTION You can correct the multiplexer internal clock devia tions by setting the value of seconds added or taken off per a day For example If the clock of multiplexers delays 2 5 seconds a day increase the value of the correction ...

Page 18: ...ess can be set up here Parameters setup parameters for selected protocol The following menus control the function of user out puts AUX1 AUX2 see Telemetry controlling on page 8 Change output by pressing one of the buttons AUX1 2 the state of user output will be changed Follow key The user output is switched on while holding the button AUX ENABLE EXTERNAL KEYBOARD marking this line you enable multi...

Page 19: ...mination at the end of the line by the connected device or must be left unconnected Cameras on divided screen are slightly shaking Interlace correction is switched off oSet up the interlace correction of live picture in menu SYSTEM DISPLAY page 16 The shaking stops with result of slower displaying At colour multiplexer displayed have incorrect colours Improper setting of camera parameters oCheck t...

Page 20: ...of the alarm inputs is defective oCheck the connection of the alarm inputs page 3 The device reacts to alarm inputs incorrectly The set up of alarm inputs polarity is incorrect oCheck the polarity of alarm inputs in menu ALARM INPUTS page 10 The alarm output relay does not react properly The polarity of alarm is set up incorrectly oSet up the normal state of alarm output in menu RELAY CONTACTS pag...

Page 21: ...pin female connector AUX INPUT Loop connection input ground GND Activity programmable Maximum alarm loop impedance 1 kW ALARM OUTPUT Number 1 potentialless contacts of low voltage relay Maximum switching voltage 40 V Maximum switching current 0 5 A RS 485 INTERFACE Baud rate depend on protocol Maximum length 1000 m Terminators 120 W at both ends CAN INTERFACE Baud rate 50 kBs Maximum length bus st...

Reviews: