IMPORTANT SAFEGUARDS 

VPP404 / VPA404 / VPA408

 

1

READ THE INSTRUCTIONS 

Be sure to read all the safety and operating instructions before using the device. 
 

KEEP THE INSTRUCTIONS 

Be sure to keep all the safety and operating instructions for possible future need and queries. 
 

FOLLOW THE INSTRUCTIONS 

Be sure to follow all the safety and operating instructions. 
 

WATER AND HUMIDITY 

Do not use the unit near water – for example near a bath tub, or in any area showing evidences 
of humidity. 
 

POWER SUPPLY 

This equipment can be fed only by the type of supply quoted by a production code on the device. 
Do not overload electric adapters and extension cords as this can result in fire or electric shock. 
 

REPAIR 

Do not attempt to open covers and to service this unit yourself, refer all repairs to qualified service 
personnel.  
 

UNPACKING 

Transfer package is a safe covering for device transportation. We recommend to keep the wrap-
ping for relevant future usage. 
 

Summary of Contents for VPA404

Page 1: ...VIDEO SWITCHER VPP404 VPA404 VPA408 Installation and user manual...

Page 2: ...Y Do not use the unit near water for example near a bath tub or in any area showing evidences of humidity POWER SUPPLY This equipment can be fed only by the type of supply quoted by a production code...

Page 3: ...rammed sequence It is possible to set up cameras which are at the right time available for automatic switching This makes possible to disconnect temporar ily uninteresting or disconnected cameras An o...

Page 4: ...o grammed sequence 3 MENU Press the button MENU to display the control menu on the screen 4 IN1 IN8 Video inputs for cameras 1 8 Pict 3 Back panel VPA404 IN 1 ALARM IN 3 IN 4 IN 2 POWER 12V 1 2 MON Pi...

Page 5: ...serve 19 Reserve 20 Common conductor ground GND 21 Reserve 22 Reserve 23 Reserve 24 Reserve 25 Common conductor ground GND Pict 6 Alarm connector CANNON 25 for VPA408 13 12 11 10 9 8 7 6 5 4 3 14 15 1...

Page 6: ...PLY INPUT The video switchers VPP404 VPA404 and VPA408 are supplied from a uniflow supply of 12 V Energy input is 4 W maximum For connecting supply voltage is used a concen tric connector 5 5 x 2 1 mm...

Page 7: ...RRECT SEQUENCE will appear In that case is necessary to set up cameras in the SEQUENCE menu pro perly TIME SWITCHING PERIOD By using the buttons 1 and 3 1 and 5 by Q8M is possible to prolong or slow d...

Page 8: ...INSTALLATION SWITCHERS CONTROLLING VPP404 VPA404 VPA408 5 after the end of the alarm event in the mode FOLLOW...

Page 9: ...does not work The supply adapter is not dimensioned sufficiently Check if the adapter power output and voltage agree with the video switchers requirements Automatic switching se quence cannot be switc...

Page 10: ......

Page 11: ...ly open Maximum alarm loop impedance 1 k Connector CANNON 25 pin socket ALARM OUTPUT Output 2 low voltage relay contacts Maximum switching voltage 40 V Maximum switching current 0 5 A TEMPERATURE COND...

Page 12: ...2000 COMPUTRONIC Printed in the Czech Republic Producer reserves the right to alternation without prior notice...