features several modes of operation and reset ability. These functions can
be changed using the following instructions by users who have rights to the supervisor
code. Modes and reset can only be modified with knowledge of the supervisor code.
Programming Single Use Mode / Non Single Mode
Non Single Mode allows the user to set the user code to be used by a single person only.
Single Use Mode allows for a revolving user code so the lock maybe used by multiple
people without having to reprogram the Receiver Latch each time.
There is a 60 second programming time limit to each step. If you time out or make an
error, programming will end and you will need to restart from step 1.
1.
We suggest reading through instructions prior to beginning programming
2.
Press and hold the Receiver Latch learn button until the yellow LED begins a
three blink pattern
3.
Enter the Supervisor pin code and press the Unlock
button
Then either
a.
Set Single Use Mode, enter 1111 and press the Lock
button
Note that this will cancel self lock mode if it has been set
Or
b.
Set Non Single Use Mode, enter 1111 and press the Unlock
Note that the user code resets to 0000 when Single Use Mode is
exited
4.
If successful the green LED will flash twice on the Receiver Latch
5.
Continue programming or enter 9999 followed by pressing the Lock
button to exit Learn Mode
6.
Test lock function for proper operation
StealthLock
®
, Keyless Invisible Security 14
Programming Self Lock Mode / Passage Mode
Self Lock Mode automatically relocks the Receiver Latch after pressing the unlock
button when a valid user or supervisor code is presented. The delay time before re-
locking the Receiver Latch can be set between 2 and 60 seconds. Passage Mode keeps
the Receiver Latch in an unlocked position after unlocking.
There is a 60 second programming time limit to each step. If you time out or make an
error, programming will end and you will need to restart from step 1.
1.
We suggest reading through instructions prior to beginning programming
2.
Press and hold the Receiver Latch learn button until the yellow LED begins a
three blink pattern
3.
Enter the Supervisor pin code and press the Unlock
button
Then either
a.
Set Self Lock, enter 2222XX and press the Lock
button
Note that this command is ignored if Single Use mode is set
XX represents the number of seconds of delay time before relocking
For example entering 222215 would result in a 15 second delay
Or
b.
Set Passage Mode, enter 2222 and press the Unlock
button
4.
If successful the green LED will flash twice on the Receiver Latch
5.
Continue programming or enter 9999 followed by pressing the Lock
button to exit Learn Mode
6.
Test lock function for proper operation