1–4
1.6
Summary of Specifications
1.6.1
Environmental & Physical
Dimensions (excluding connectors)
See Figure 1-4
Temperature
Operating
ODU: BUC-4000
-40º
–
122ºF (-40º to 50ºC)
IDU: LBC-4000
14º
–
122ºF (-10º to 50ºC)
Non-operating
ODU: MBT-4000
-58º
–
160ºF (-50º to 71ºC)
Operational Humidity
5
–
95 non-condensing
Operational Altitude
10,000 ft above sea level
Prime Power
90
–
260 VAC, 47-63 Hz
External Reference Input
Either 5 MHz or 10 MHz
5 dBm optional
Frequency Stability
Over time
1x10
-9
/day, 1x10
-7
/year
Over temperature
40º
–
55ºC, 1x10
-8
1.6.2
BUC-4000 Block Up Converter ODU
Input Frequency Range
950 – 2000 MHz
Output Frequency
(by model)
BUC-4000C
5860 – 6650 MHz
BUC-4000X
7900 – 8400 MHz
BUC-4000Ku
13.75 – 14.50 GHz
BUC-4000Ka
30.00 – 31.00 GHz
27.50 – 28.50 GHz (optional)
28.50 – 29.50 GHz (optional)
29.50 – 30.10 GHz (optional)
Input/Output Impedance
50
Input Return Loss
15 dB minimum
Output Return Loss
18 dB minimum
Input Connector
Type ‘N’ Female
Output Connector
Type ‘N’ Female (C-, X-, and Ku-Band)
Gain
15 dB nominal at minimum attenuation
(18 dB for Ku-Band BUC)
User Attenuation Range
0 – 10 dB
Output Power, P1dB
+10 dBm minimum
Third Order Intercept
+20 dBm minimum
Spurious
Carrier Related
-60 dBc
Non-Carrier Related
-60 dBm
Summary of Contents for MBT-4000
Page 14: ...MBT 4000 Multi Band Transceiver System Revision 6 Preface vi Notes ...
Page 20: ...1 6 1 7 Dimensional Envelope Figure 1 4 MBT 4000 Dimensional Envelope ...
Page 21: ...1 7 Notes ...
Page 42: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 4 MN MBT4000 IOM ...
Page 43: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 5 MN MBT4000 IOM ...
Page 45: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 7 MN MBT4000 IOM Notes ...
Page 83: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...