Concise Alarm
Status
N/A
All
20 bytes,
numeric
Query only.
Used to query the alarm status of the unit.
Example:
<0001/CAS?{cr}
>0001/CAS=abcdefghijkl{cr}{lf}
Where:
a through l = 0 or 1, 0=OK, 1=FLT
All:
a=+15V Power Supply
b=+7.5V Power Supply
c=+5.0V Power Supply
MBT-4000:
d=+28V Power Supply
e=Ref Oscillator Lock Detect
f=Intermodule Communications
g=Max current on LNA power supply AUX COMM1
h=Max current on LNA power supply AUX COMM2
i=Current window LNA power supply AUX COMM1
j=Current window LNA power supply AUX COMM2
k=Fault input AUX COMM1 (Pin F, J9)
l=Fault input AUX COMM2 (Pin F, J8)
BDC/BUC:
d=X (reserved for future use)
e=Synthesizer Lock Detect
f=Heat-sink Temperature
g=LNA current (BDC only, reserved on BUC)
h=Reserved, always zero
i-l=Not sent.
N/A
CAS?
CAS=x…X
(see description
for details of
arguments)
Summary of Contents for MBT-4000
Page 14: ...MBT 4000 Multi Band Transceiver System Revision 6 Preface vi Notes ...
Page 20: ...1 6 1 7 Dimensional Envelope Figure 1 4 MBT 4000 Dimensional Envelope ...
Page 21: ...1 7 Notes ...
Page 42: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 4 MN MBT4000 IOM ...
Page 43: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 5 MN MBT4000 IOM ...
Page 45: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 7 MN MBT4000 IOM Notes ...
Page 83: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...