LNA Current
Window
LCW=sxx
MBT
s=1 byte,
value of 1, 2
1=LNA A
2=LNA B
xx=2 bytes,
numeric
Command or Query.
This command allows the user to set the alarm window in
% of
the calibrated LNA Current. Valid inputs are 20 to 50 in
increments of 1%. In addition, setting the value to 99 disables
the alarm function.
Default is
Disabled
.
Example:
LCW=130, set alarm window for LNA A (Aux Comm
1) to
30%.
LCW= (message ok)
LCW? (received ok,
but invalid arguments
found)
LCW* (message ok,
but not permitted in
current mode)
LCW! (command not
accepted by BUC or
BDC sub-units)
LCW?s
LCW=sxx
(same format as
command
arguments)
LNA Fault
Logic
LFL=sx
MBT
s=1 byte,
value of 1, 2
1=LNA A
2=LNA B
x=1 byte,
Value of 0, 1
0 = Disable
1 = Enable
Command or Query.
Allows LNA Fault Logic to contribute to the summary fault relay,
where:
s = Source:
1=LNA A (Aux Comm 1)
2=LNA B (Aux Comm 2)
x = Enable:
0 = Disabled
1 = Enabled
Example:
LFL=11
LFL= (message ok)
LFL? (received ok,
but invalid arguments
found)
LCS* (message ok,
but not permitted in
current mode)
LFL! (command not
accepted by BUC or
BDC sub-units)
LFL?s
s=1 byte,
Value of 1, 2
LFL=sx
(same format as
command
arguments)
LNA Fault
Logic
LFL=x
BDC
x=1 byte,
Value of 0, 1
0 = Disable
1 = Enable
Command or Query.
Allows LNA Fault Logic to contribute to the summary fault relay
as follows:
Enable
0 = Disabled
1 = Enabled
Example:
LFL=1
LFL= (message ok)
LFL? (received ok,
but invalid arguments
found)
LCS* (message ok,
but not permitted in
current mode)
LFL! (command not
accepted by BDC
sub-units)
LFL?
LFL=x
(same format as
command
arguments)
Summary of Contents for MBT-4000
Page 14: ...MBT 4000 Multi Band Transceiver System Revision 6 Preface vi Notes ...
Page 20: ...1 6 1 7 Dimensional Envelope Figure 1 4 MBT 4000 Dimensional Envelope ...
Page 21: ...1 7 Notes ...
Page 42: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 4 MN MBT4000 IOM ...
Page 43: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 5 MN MBT4000 IOM ...
Page 45: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 7 MN MBT4000 IOM Notes ...
Page 83: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...