MBT-4000 Multi-Band Transceiver System
Revision 6
Remote Control
MN/MBT4000.IOM
Remote Control
A–19
MN/MBT4000.IOM
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Reference
Oscillator
Adjust
REF=xxxx
MBT
4 bytes,
numeric
Command or Query.
Ref Osc Adjust, between 0000 and 0255.
Resolution 0001.
Example:
REF=0197
Note:
REF cannot be adjusted when the unit is locked to an
external reference source.
REF= (message OK)
REF? (received OK,
but invalid arguments
found)
REF* (message OK,
but not permitted in
current mode)
REF?
REF=xxxx
(same format as
command
arguments)
Retrieve
Equipment
Type
N/A
All
22 bytes,
alphanumeric
Query only.
The unit returns a string indicated the Model Number and the
software version installed
Example:
RET=BUC-4000 VER:1.0.3
N/A
RET?
RET=x….x
(see description
for details of
arguments)
Summary of Contents for MBT-4000
Page 14: ...MBT 4000 Multi Band Transceiver System Revision 6 Preface vi Notes ...
Page 20: ...1 6 1 7 Dimensional Envelope Figure 1 4 MBT 4000 Dimensional Envelope ...
Page 21: ...1 7 Notes ...
Page 42: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 4 MN MBT4000 IOM ...
Page 43: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 5 MN MBT4000 IOM ...
Page 45: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 7 MN MBT4000 IOM Notes ...
Page 83: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...