MBT-4000 Multi-Band Transceiver System
Revision 6
Remote Control
MN/MBT4000.IOM
Remote Control
A–24
MN/MBT4000.IOM
Parameter
Type
Command
(Instruction
Code and
qualifier)
Valid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Mute offline
OFM=um
MBT
u=1 byte,
value of 1, 2
1=Unit 1
2=Unit 2
m=1 byte,
Value of 0, 1
0 = Manual
1 = Automatic
Command or Query.
This command allows the user to enable muting for offline unit
when in redundancy mode.
Note:
The offline unit must start out as online for this command.
Where:
OFM=10 would be existing behavior for the block in slot 1.
OFM=11 would force a mute of the block in slot one if slot one is
offline as indicated by the switch position(blinking yellow or red
LED). It would force an "un- mute" of the block in slot one if slot
one is online and not faulted as indicated by the switch
position(steady green LED).
OFM=20 would be existing behavior for the block in slot two.
OFM=21 would force a mute of the block in slot one if slot two is
offline as indicated by the switch position(blinking yellow or red
LED). It would force an "un- mute" of the block in slot two if slot
two is online and not faulted as indicated by the switch
position(steady green LED).
These settings would be kept in NVRAM and would come from
the factory as "OFM=10" and "OFM=20"
Also, the offline unit must not be muted during this time.
The offline unit has to be set for online, otherwise the OFM
command won't work properly.
OFM= (message OK)
OFM? (received OK,
but invalid arguments
found)
OFM! (command not
accepted
RAM?u
u=1 byte,
Value of 1, 2
RAM=um
(same format as
command
arguments)
Summary of Contents for MBT-4000
Page 14: ...MBT 4000 Multi Band Transceiver System Revision 6 Preface vi Notes ...
Page 20: ...1 6 1 7 Dimensional Envelope Figure 1 4 MBT 4000 Dimensional Envelope ...
Page 21: ...1 7 Notes ...
Page 42: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 4 MN MBT4000 IOM ...
Page 43: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 5 MN MBT4000 IOM ...
Page 45: ...MBT 4000 Multi Band Transceiver System Revision 6 Flash Upgrading 5 7 MN MBT4000 IOM Notes ...
Page 83: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...