CRS-280/280L IF Switch for 1:N Redundancy
Revision -
Connector Pinouts
3–5
MN-CRS-280/280L
Table 3-2 summarizes the connectors, grouped according to location (front, rear, or data
interface) and service function.
Table 3-2. CRS-280L External Connectors (Front and Rear Panel)
Connector Group
Name
Connector Type
Function
Front
Panel
IF
(Transmit IF)
22X Type ‘N’ 50Ω
female
L-Band
Input
Tx Backup
Test Out
Tx In
Tx Traffic 1-
10
Up Link Out
Tx In
(Receive IF)
22X Type ‘N’ 50Ω
female
L-Band
Output
Rx Backup
Test In
Rx Out
Rx Traffic 1-
10
Down Link In
Rx out
Rear Panel Control
Interface
J1
CRS Control
Interface
25-pin Type ‘D’ female
Control interface for CRS-400**, CRS-300,
CRS-500 Redundancy Switching products
J2 SMS Control
Interface
15-pin Type ‘D’ male
Control interface for SMS-7000**
Redudancy Switching Product
Power / Ground AC Input
2X IEC
p/o Primary and Backup AC Power Supply
Modules (CEFD P/N PL/10207-1)
DC Input
2X 3-screw Terminal
Block
p/o Optional Primary and Backup DC
Power Supply Modules (CEFD P/N PL-
0000355)
Ground
#10-32 stud
Common Chassis Ground
** Indicates a Comtech EF Data legacy product that is no longer in production.
The European EMC Directive (EN55022, EN50082-1) requires using properly shielded cables for DATA
I/O. These cables must be double-shielded from end-to-end, ensuring a continuous ground shield.
Summary of Contents for CRS-280
Page 28: ...CRS 280 280L IF Switch for 1 N Redundancy Revision Introduction 1 14 MN CRS 280 280L Notes ...
Page 68: ...CRS 280 280L IF Switch for 1 N Redundancy Revision Appendix B B 8 MN CRS 280 280L BLANK PAGE ...
Page 69: ......
Page 70: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...