DM240XR High-Speed Digital Modulator
SNMP
MN-DM240XR– Revision 12
8–5
g703E3(4),
g703T3(5),
sts1(6),
hssi(7),
parallelDVB(8),
parallelM2P(9),
none(10),
directv(11),
oc3(13),
stm1(14),
g703E2(15),
g703T2Bal(16),
g703T2Unbal(17),
g703E1Bal(18),
g703E1Unbal(19),
g703T1AMI(20),
g703T1B8ZS(21),
gigEthernet(22)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the various interface types.
The following choices are not supported:
none(10),
oc3(13),
stm1(14)
Note: Selecting interface types Parallel DVB,
Parallel M2P, Serial, DirecTv or HSSI will force the
outclock selection to SCT. Selecting interface type
ASI Norm or ASI Null causes the outclock selection to
be forced to None.
"
::= { radSNMPModNVStatus 14 }
radClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
inverted(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects clock polarity for Tx terrestrial clock
relative to Tx data."
::= { radSNMPModNVStatus 15 }
radDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
inverted(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects data polarity"
::= { radSNMPModNVStatus 16}
radSpectrum OBJECT-TYPE
SYNTAX INTEGER {
inverted(0),
normal(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Inverts the symbol mapping direction of rotation."
::= { radSNMPModNVStatus 17 }
radModulationType OBJECT-TYPE
SYNTAX INTEGER {
qpsk(0),
bpsk(1),
psk8(2),
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...