DM240XR High-Speed Digital Modulator
SNMP
MN-DM240XR– Revision 12
8–13
DESCRIPTION
"Selects the backup delay in 100ms steps for the Gig Ethernet card."
::= { radSNMPModNVStatus 61 }
radTerrEthAddrPrime OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the prime IP address for the Gig Ethernet card."
::= { radSNMPModNVStatus 62 }
radTerrEthUdpPortPrime OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the prime UDP port for the Gig Ethernet card."
::= { radSNMPModNVStatus 63 }
radTerrEthSourcePrime OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the prime source IP address for the Gig Ethernet card."
::= { radSNMPModNVStatus 64 }
radTerrEthAddrBackup OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the backup IP address for the Gig Ethernet card."
::= { radSNMPModNVStatus 65 }
radTerrEthUdpPortBackup OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the backup UDP port for the Gig Ethernet card."
::= { radSNMPModNVStatus 66 }
radTerrEthSourceBackup OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the backup source IP address for the Gig Ethernet card."
::= { radSNMPModNVStatus 67 }
radTerrEthAddrUnicast OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the Unicast IP address for the Gig Ethernet card."
::= { radSNMPModNVStatus 68 }
radSatFraming OBJECT-TYPE
SYNTAX INTEGER {
dvbs(0),
dvbs2Normal(1),
dvbs2Short(2),
dssDtv(3)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the satellite framing. SatFraming is valid in every radMode
(networkSpec), except DVB-S2-NBS. In that configuration, the framing
is automatically determined by the incoming stream."
::= { radSNMPModNVStatus 69 }
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...