DM240XR High-Speed Digital Modulator
Remote Operations
MN-DM240XR– Revision 12
9–6
<1>
BB Scrambler
Bypass
0 = Normal, 1 = Bypass
<1>
Outer FEC
Bypass
0 = Normal, 1 = Bypass
<1>
Test Pattern
0 = None, 1 = 2
15
– 1, 23 = 2
23
-1
<1>
Last Rate
Control
0 = Symbol Rate, 1 = Data Rate, 2 = Auto
<1>
Interleaver
Bypass
0 = Bypass, 1 = Normal
<1>
PCR
Restamping
0 = Off, 1= On
<1>
Multi-PIIC
Mode
1 = Manual,
2 = Redundancy
<1>
Redundancy
Mode
0 = Force Prime,
1 = Force Backup,
2 = Manual Revert,
3 = Auto-Revert
<1>
Prime PIIC Slot
1 – 3
<1>
Backup PIIC
Slot
1 – 3
<1>
Pilot Symbols
0 = Off, 1= On
<1>
Inner FEC
Bypass
0 = Normal, 1 = Bypass
<1>
PL Scrambler
Bypass
0 = Normal, 1 = Bypass
<2>
Reserved
Set to 0
<2>
Reserved
Set to 1
<4>
Gold Code Seq
Index
0 to 262142
<1>
Sat Framing
3=DVB-S, 5=DTV, 10=DVB-S2 Normal, 15=DVB-S2 Short
Status Bytes
<1>
Reserved
<1>
Reserved
<1>
Reserved
<1>
Major Alarm
Bit 0 = Spare
Bit 1 = Transmit Oversample PLL Lock
Bit 2 = FPGA Config Error
Bit 3 = IF Synthesizer PLL Lock
Bit 4 = External Reference PLL Lock
Bit 5 = Composite PLL Lock
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...