DM240XR High-Speed Digital Modulator
Remote Operations
MN-DM240XR– Revision 12
9–14
Opcode: <245Ch>
Query Multi-PIIC Configuration
<1>
Multi-PIIC
Mode
1 = Manual,
2 = Redundancy
<1>
Redundancy
Mode
0 = Force Prime,
1 = Force Backup,
2 = Manual Revert,
3 = Auto-Revert
<1>
Prime PIIC Slot
1 – 3
<1>
Backup PIIC
Slot
1 – 3
Opcode: <245Dh>
Query Multi-PIIC Status
<1>
Active PIIC Slot 1 – 3
<1>
Slot 1 PIIC Type 0x13 = ASI
<1>
Slot 2 PIIC Type 0x00 = INVALID
0x93 = ASI
0x94 = RS422 Parallel
0x95 = LVDS Parallel
0x96 = HSSI
0x9C = DirecTV (PECL)
0x9D = Ethernet
0xD3 = ASI Out (Monitor)
0xA1 = Auto EQ
0xE2 = RS422/530 Serial
0xFF = None
<1>
Slot 3 PIIC Type 0x00 = INVALID
0x93 = ASI
0x94 = RS422 Parallel
0x95 = LVDS Parallel
0x96 = HSSI
0x9C = DirecTV (PECL)
0x9D = Ethernet
0xD3 = ASI Out (Monitor)
0xA1 = Auto EQ
0xE2 = RS422/530 Serial
0xFF = None
<1>
PIIC Clock
Activity
Bit 1 = Slot 1 Activity
Bit 2 = Slot 2 Activity
Bit 3 = Slot 3 Activity
<1>
PIIC Data
Activity
Bit 1 = Slot 1 Activity
Bit 2 = Slot 2 Activity
Bit 3 = Slot 3 Activity
Opcode: <2552>
Query Terrestrial COP3 Ethernet Configuration
<8>
Mac Address
Binary Value
<1>
Ethernet Mode
0=UDP 1=COP3 2=COP3 FEC
<1>
Online Select
0=Prime 1=Backup
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...