DM240XR High-Speed Digital Modulator
Web Browser
MN-DM240XR– Revision 12
10–12
The IP Address of the Local Network Router. If a router is
present on the local network, this address must be consistent
with the IP Mask and the subnet of the modem. If no router is
present, then the address should be set to a foreign address. This
address is expressed in decimal format. Broadcast and loop back
addresses will not be allowed. These are addresses with all
subnet bits set to 0’s or 1’s.
Configuring Applications
Figure 10-7. Configuring Applications
SNMP Setup:
SNMP Version:
{V1 & 2, V3} Default = V1 & V2
Trap Version:
{V1 & 2} Default = V1
Authorization:
{TRAPS ON, TRAPS OFF} Default = TRAPS OFF
Read Community:
{Public} Default
Read/Write Community:
{Public} Default