MN-DM240XR– Revision 12
2–1
Chapter 2.
Installation
This section provides unpacking and installation instructions, and a description of external
connections and backward alarm information.
2.1
Installation Requirements
The DM240 can be installed within any standard 19-inch equipment cabinet or rack, and requires
1 RU mounting space (1.75 inches) vertically and 17 inches of depth. Including cabling, a
minimum of 20-inches of rack depth is required. The rear panel of the DM240XR
is designed to
have power enter from the left and IF cabling enter from the right when viewed from the rear of
the unit. Data and control cabling can enter from either side although they are closer to the
center. The unit can be placed on a table or suitable surface if required.
WARNING
PROPER GROUNDING PROTECTION: During installation and setup, the
user must ensure that the unit is properly grounded. The equipment shall
be connected to the protective earth connection through the end use
protective earth protection.
In addition, the IF input and output coax cable shielding must be properly
terminated to the chassis/unit ground.
WARNING
There are no user-serviceable parts or configuration settings located
inside the DM240 Chassis. There is a potential shock hazard internally at
the power supply module. DO NOT open the DM240 Chassis under any
circumstances.
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...