DM240XR High-Speed Digital Modulator
User Interfaces
MN-DM240XR– Revision 12
4–24
ROUTER IP ADDR
{XX.XX.XX.XX} Hexidecimal Address
{ddd.ddd.ddd.ddd} Decimal Address
The IP Address of the Local Network Router. If a router is
present on the local network, this address must be consistent
with the IP Mask and the subnet of the modem. If no router is
present, then the address should be set to a foreign address. This
address is expressed in hexadecimal format.
Broadcast and loop back addresses will not be allowed. These
are addresses with all subnet bits set to 0’s or 1’s.
SERVER IP ADDR
{XX.XX.XX.XX} Hexidecimal Address
{ddd.ddd.ddd.ddd} Decimal Address
The IP Address of the Boot Server and the address of the SNMP
Trap Server when SNMP is active. If a server is used and there
is no local router, this address must be consistent with the
modem address. If a router has been specified, the address is
presumed to be reachable via the router. Broadcast and loop
back addresses will not be allowed. These are addresses with all
subnet bits set to 0’s or 1’s.
To change the display from Decimal to Hexidecimal on the IP ADDRESS
MASK, MODEM IP ADDRESS, SERVER IP ADDRESS, AND
ROUTER IP ADDRESS menus, press all four arrow keys
simultaneously.
MODEM EADDR
{001065010000}
Displays the Ethernet address of the device. Set at the factory
and is a unique identifier for the Ethernet physical interface.
ETHER RATE
{10 MBPS/HD, 10 MBPS/FD, AUTO NEGOTIATE, 100
MBPS/FD, 100 MBPS/HD}
The data rate for the local Ethernet Interface.
10 Mbps/HD: 10 Base-T half-duplex
10 Mbps/FD: 10 Base-T full duplex.
SNMP (menu)
A description of OID organization is provided in the MIB
portion of this manual (Appendix C).
SNMP VERSION
{V1 & V2, V3}
This selection controls the SNMP Version that will be used in
messaging between the equipment and it’s host.
When V1 & V2 is used, RD COMMUNITY and RDWR
COMMUNITY are used to determine the authorization of an
incoming message.
IMPORTANT
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...