DM240XR High-Speed Digital Modulator
User Interfaces
MN-DM240XR– Revision 12
4–28
FTP (menu)
PORT:
{XXXX}
FTP Port number must be set the same value on DM240XR
and FTP program
USER ID:
{xxxxxxxx}
User to select USER ID. The user can modify the user ID. The
user ID can have up to 14 characters supporting alpha and
numeric characters. Alpha characters can be entered using the up
and down arrow keys. Numeric characters can be selected by
using the number keys on the front panel. The user can clear all
characters from the front panel screen.
PASSWORD:
{xxxxxxxx}
User to select PASSWORD ID. The user can modify the
PASSWORD. The password can have up to 14 characters
supporting alpha and numeric characters. Alpha characters can
be entered using the up and down arrow keys. Numeric
characters can be selected by using the number keys on the front
panel. The user can clear all characters from the front panel
screen.
BACK CHANNEL (menu)
The Auto EQ Back Channel menu is used to support remote
equalization with the AutoEQ system, the equalization data is
transported over TCP/IP using a backchannel protocol. Before
setting up the backchannel, perform the TCP/IP Ethernet setup as
outlined in Appendix B of the user manual. This document is to
be used only as a guideline for setting up the backchannel
menus. Contact the Network administrator for proper guidance
and support to ensure setup is successful.
LOCAL PORT:
{XXXX}
The local port number must be set to the same value at both the
local and remote sites.
SERVER PORT:
{XXXX}
The server port number must be set to the same value at both the
local and remote sites.
Note: The local port and server port values must be different from
the local and remote sites.
SERVER IP ADDR:
{XXX.XXX.XXX.XXX} Hexidecimal Address
{ddd.ddd.ddd.ddd} Decimal Address
On the local unit, this should have the value of the remote unit’s
IP address.
Note: If the remote IP address is not publicly accessible then
its translated NAT(Network Address Translation) needs to be
applied.
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...