Operation
MNC-0400-071
Page 47 of 53
Revision 4
Initial Setup and Operation
General
The amplifier can be operated from the Front Panel (LOCAL configuration) or from a
remote controller (REMOTE configuration). The amplifier is configured at the factory
with the default values shown in table 1. These values allow immediate operation of the
amplifier when the amplifier is connected to an operational load or a dummy load
capable of dissipating rated RF output power.
Parameter
Default Value
Gain
Minimum Gain
Local/Remote
LOCAL
RF Inhibit
OFF
System Offset
0.0 dB
Max Power Trip
OFF
Min Power Trip
OFF
Max Reflected
Power
OFF
Audio Alarm
ON
COM 1
9600 Baud, 8/1, None
COM 2
Address “A” 9600 Baud,8/1, None
Ethernet
DHCP
Constant Power
OFF
Heater Standby
ON
HV state @startup
Restore
Power Units
dBm
Temperature Units
Centigrade
Table 2. Default Values
Note:
Refer to the chapter titled
Overview
for general amplifier specifications and chapter 8,
System
operation XTRT series amplifiers
for specifications that are specific to your particular amplifier.