MNC-0500-038
25 of 28
Revision 2
Amplifier Communication and Protocol, XTRT, Touchscreen TWTA
Redundancy Switch Control
Command Byte:
‘U’
Format:
‘U3’ Activate override mode and switch in Amplifier Switch 2.
‘U2’ Activate override mode and switch in other Amplifier Switch 2.
‘U1’ Activate override mode and switch in Amplifier Switch 1.
‘U0’ Activate override mode and switch in other Amplifier Switch 1.
‘UM’ Activate overide mode.
‘UA’ Terminate overide mode, activating automatic mode.
Notes: When sending a ‘U3‘, ‘U2’, ‘U1’ or ‘U0’ command, also send a ‘UM’ command to the other amplifier to
prevent unwanted automatic-mode switches.
Set Serial Configuration
Command Byte
: 'X'
Function
: Configures serial communications on the specified port. Use this command carefully as it could cause
you to lose communications with the amplifier. See the
Get Serial Configuration
query for a related command. To
configure the serial port, use Parameter Format 1. To configure RS-485, use Parameter Format 2.
Parameter Format 1
: "CBBBBBBPDS"
C Communications port to configure 1=COM1, 2=COM2.
BBBBBB Desired baud rate:
057600, 038400, 019200, 009600, 004800, 002400, 001200
P Parity, 'N', 'O', or 'E'.
D Data bits, '8' or '7'.
S Stop bits, '1'.
Parameter Format 2:
“RABC”
Response
: "ABC"
A ‘4’ or ‘2’ Wire
B ‘T’ (Terminated) or ‘U’ (Unterminated)
C RS 485 address
Notes
:
1) The parameters listed represent all options currently available.
2) The leading zero on the baud rate is there to facilitate selection of higher baud rates in future software revisions.
3) Amplifiers currently support just two data/stop configurations: 8/1 and 7/2. Thus byte "S" is a placeholder.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.