MNC-0500-038
26 of 28
Revision 2
Amplifier Communication and Protocol, XTRT, Touchscreen TWTA
Time and Date
Command Byte:
‘%’
Function:
Sets the Amplifier internal clock. The clock is referenced when time stamping events as they are
recorded.
Parameter: “YYYY/MM/DD, hh:mm”
Example:
2002/02/08, 13:01
YYYY = 2002
MM = 02
DD = 08
hh = 13
mm = 01
Note: The hours are in 24 hour format.
Reset Processor
Command Byte
: '~'
Function
: Resets the processor.
Heater Standby
Command Byte
: ':'
Function
: Enables/Disables Heater Standby mode.
Parameters
:
'0' - Disable Heater Standby.
'1' - Enable Heater Standby.
Note:
The “XTRT Series Amplifiers” power up with heater standby enabled.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.