Unpacking and Installation
MNC-0300-070
6 of 22
Revision 1
The specific installation details are dependent upon the cabinet
design. Two front mounting brackets (3 inches long) and two
back mounting brackets (9 inches long) are supplied. See
appendix titled
Mechanical Drawings
for specific mounting
instructions pertaining to your amplifier.
Waveguide Connection
The RF output waveguide port is located on the rear panel of
the amplifier. Ensure that the proper matching waveguide flange
is used to connect the amplifier output to the RF load. See
Figure 1 “, Typical 4 Screw Mounting Flange Tightening
Sequence“, and Figure 2, Typical 8 Screw Mounting Flange
Tightening Sequence.
Caution
When not connected to the external waveguide
system or a terminated load, waveguide flanges
should be covered with a protective cap or tape
that does not leave glue residue when removed.
Xicom recommends the use of Kapton® tape, 3M
Brand, #92, Xicom P/N 602-0001-001. Remove
tape or cap prior to final installation. Failure to
comply could result in contamination to the internal
waveguide system or TWT and equipment
damage.
Vorsicht
Wenn Hohlleiter-Flansche nicht mit dem externen
Hohlleiter-System oder einer terminierten
Belastung verbunden sind, sollten sie mit einer
Schutzkappe oder Band abgedeckt werden, das
beim Entfernen keine Kleberrückstände hinterlässt.
Xicom empfiehlt die Verwendung von Kapton®
Band, 3M Brand, #92, Xicom P/N 602-0001-001.
Band oder Kappe vor der endgültigen Aufstellung
entfernen. Nichtbefolgen könnte Verunreinigung
des internen Hohlleitersystems oder Beschädigung
von TWT und Gerät zur Folge haben.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.