HE4000 Encoding System
Using a Remote Unit
HE4000 Remote Command Descriptions
Remote Command
Parameter
Range
Factory
Default
Description
MC SN
-
Factory
preset
Serial
Number
Displays the system serial number
This command does not take any parameters
MC STOP
1
2
1
Sets the serial port stop bits
MC TIME
hh:mm:ss
Numeric value
in the format:
hh:mm:ss
-
Sets the HE4000 internal real-time clock. The time
is set in hh:mm:ss format where:
● hh = hours, in a 24-hour format, from 00 to
23, where 00 is midnight and 23 is 11 PM
● mm = minutes from 00 to 59
● ss = seconds from 00 to 59
For example, to set the time to 10:20:59 AM, issue
the command MC TIME 10:20:59. To set the time
to 10:20:59 PM, issue the command MC TIME
22:20:59.
Note: The HE4000 real- time clock does have a
battery backup source. If the unit loses power,
is turned off, or reset, the real-time clock is set
to the current (correct) day and time.
MC TIMEZONE
<parameter>
HH.MM
0:00
>mc timezone ?
Sets the offset from GMT
The time zone is entered in hours and minutes, e.g.
-8:00
MC VERSION
-
-
Displays the firmware version of the master
controller card.
Front panel command equivalent: none
MC UPDATE
Software update – refer to software upgrade
instructions provided with your new software
package.
MOD CAR_TYPE
NORM, CW
NORM
Norm – Normal modulation
CW – Pure CW carrier
4-20 01 -0951-404 Rev B