Using a Remote Unit HE4 000 Encoding System
PID HD PCR
<number>
32 – 8191
49 (0x0031)
Sets the PCR PID for the HD program
Valid PIDs are in the range 32 to 8191 decimal.
PIDs may be entered in hex with a leading "0x", e.g.
0x100
PID HD PGCA
<number>
32 – 8191
61 (0x003d)
Sets the PGCA PID for the HD program
Valid PIDs are in the range 32 to 8191 decimal.
PIDs may be entered in hex with a leading "0x", e.g.
0x100
PID HD PMT
<number>
32 – 8191
48 (0x0030)
Sets the PMT PID for the HD program
Valid PIDs are in the range 32 to 8191 decimal.
PIDs may be entered in hex with a leading "0x", e.g.
0x100
PID HD VIDEO
<number>
32 – 8191
49 (0x0031)
Sets the HD VIDEO PID for the HD program
Valid PIDs are in the range 32 to 8191 decimal.
PIDs may be entered in hex with a leading "0x", e.g.
0x100
PID MODE
Auto
Manual
auto
Sets the PID mode.
Changing the PIDs is not recommended If any PID
is changed, the PID MODE will be set to manual.
Changing the PID MODE back to auto will restore all
PIDs to the ‘correct’ values.
PID SD PMT
<number>
32 – 8191
32 (0x0020) Sets the PMT PID for the HD program
Valid PIDs are in the range 32 to 8191 decimal.
PIDs may be entered in hex with a leading "0x", e.g.
0x100
PID SD VIDEO
<number>
32 – 8191
33 (0x0021)
Sets the SD VIDEO PID for the SD program
Valid PIDs are in the range 32 to 8191 decimal.
PIDs may be entered in hex with a leading "0x", e.g.
0x100
PID SD PCR
<number>
32 – 8191
33 (0x0021)
Sets the SD PCR PID for the SD program
Valid PIDs are in the range 32 to 8191 decimal.
PIDs may be entered in hex with a leading "0x", e.g.
0x100
PID SD PGCA
<number>
32 – 8191
45 (0x002d)
Sets the SD PGCA PID for the SD program
Valid PIDs are in the range 32 to 8191 decimal.
PIDs may be entered in hex with a leading "0x", e.g.
0x100.
01-0951-404 Rev B
4-23