Using a Remote Unit
HE4000 Encoding System
HE4000 Remote Command Descriptions
Remote Command
Parameter
Range
Factory
Default
Description
out smpte 19
out summary
OUT BRIGHT
0 – 10
8
Sets the video output brightness
OUT BITRATE
1000000
65000000
19392658
Sets the output bitrate
OUT ENABLE
ON, OFF
On
Enables the transport stream
OUT MONAUD
ANALOG
AESEBU
<port>
A
Sets the audio monitor source
ANALOG Analog Audio Input
A AESEBU Audio Input A
B AESEBU Audio Input B
C AESEBU Audio Input C
D AESEBU Audio Input D
OUT MONLCD
ANALOG
SD
HD
HD
Sets the LCD video source
ANALOG SD Composite
SD SD SDI
HD HD SDI
OUT SMPTE
OFF
19
38
19
Sets the SMPTE bitrate mode
OFF Off
19 On 19.39Mbps
38 On 38.78Mbps
OUT SUMMARY
-
See
Description
Displays a program summary
This command is query-only
3:(HDV,A,B,C,D) 2:(SDV)
Above example, 3 represents HD service ID. HD
video, and audio A, B, C, D are assign to the HD
program. Service 2 is the SD video which is enabled
with no audios.
TAB CARRIER_HZ
50,000,000 to
1750,000,000
566310000
Hz
Sets the carrier frequency when ATSC table types
are enabled.
TAB HD
ATSC_NAME
<
string
>
<
string
>
CH3 HD
Sets the ATSC name; up to 8 characters may be
used.
TAB HD MAJORCH
< number >
1 to 99
31
Sets the HD major channel in the ATSC tables.
TAB HD MINORCH
< number >
1 to 99
3
Sets the HD minor channel in the ATSC tables.
TAB HD PROGNUM
< number >
1 to 65535
3
Sets the HD program number
The parameter is a decimal number.
4-24