HE4000 Encoding System
Using a Remote Unit
ComtechTV standard product NMS backward compatibility
For compatibility with NMS designs based around the ComtechTV TE6000 modular products, the
HE4000 will accept slot numbers in mnemonics. For example:
AE A BR 256000 sets the Audio A bit rate to 256000. The HE4000 will accept AE.1.A BR 256000
as an alternative. The slot number is accepted but ignored.
Configuration examples:
Here is a sample power up initialization screen:
>
HE4000 PURECODER HD/SD MPEG2
Encoder
Software Version: 3.07
Date of Make: 03/01/2007
Time of Make: 02:18:45
Initializing Master Controller
... done
Initializing Output ... done
Initializing HD Video ... done
Initializing SD Vi deo ... done
Initializing Audio A ... done
Initializing Audio B ... done
Initializing Audio C ... done
Initializing Audio D ... done
>
>
Here is a sample of a general query of commands available.
>?
The following commands are supported:
MC monitor and control
FM fault manager
CM configuration manager
HD HD video encoder
SD SD video encoder
AE.x audio encoders, where 'x' is A, B, C or D
UD.A asynchronous user data
EXT external ASI input
OUT output controller
TAB PSIP table generator
PID manual PID overrides (not recommended)
CA conditional access
VAR enable/disable variants
For more information on a command, type the command followed by a question mark
>mc ?
The Master Controller commands are:
MC DESCR displays the system description
MC CONTACT sets contact info for the system
MC NAME sets the system name
MC LOCATION sets the system location
MC SN displays the system serial number
MC VERSION displays the software version
The serial port commands are:
MC BAUD sets the serial port baud rate
MC DATA sets the serial port data bits
MC PARITY sets the serial port parity
MC STOP sets the serial port stop bits
MC FLOW sets the serial port flow control
The network commands are:
MC MAC displays the ethernet MAC address
MC IP sets the IP address