HE4000 Encoding System
Configuring the HE4000
C onfiguring the H E 4000
5
This chapter presents the following information:
•
Configuration prerequisites.
•
A high-level procedure used to configure a HE4000 using either the front panel or a
remote unit.
•
Detailed procedures for configuring a HE4000 to the default standards, using either
the front panel or a remote unit
•
Examples of common HE4000 configurations, including:
•
Configuring a basic DSNG setup using the front panel.
5.0 HE4000 Configuration Procedure
Whether the front panel or a remote unit is used to configure the HE4000, perform the following
steps to configure the system:
1.
Make a list of the operational requirements.
2.
Compare the requirements to the corresponding HE4000 default parameter settings
3.
Determine which HE4000 default parameters must be changed for the operational
requirements.
4.
Record the new HE4000 parameter values and the corresponding front panel or remote
commands required to change those parameters.
5.
Configure the HE4000 to the default configuration.
6.
Configure the HE4000 with any new parameters.
7.
Ensure that any decoders are correctly configured to operate with the HE4000 parameter
settings.
All HE4000 configuration changes issued from the front panel are
automatically save to non-volatile memory. Unlike front panel operations,
HE4000
parameter
changes
made
from
a
remote
unit
are
not
automatically saved to non-volatile memory. If configuration changes are
made from a remote unit, issue the command
CM
SAVE
to save the
configuration to non-volatile memory. Multiple configurations can be
saved using the QuickSet commands.
01-0951-404 Rev B
5-1