The HE4000 contains a very sophisticated fault management system. The fault system may be
customized by the sophisticated user for their particular requirements. Every defined fault may be
individually enabled or disabled and every fault may be individually defined to affect or not affect
the fault relay. All faults have been pre-defined at the factory. The pre-defined fault masking will
suffice for most customers in most situations. Sophisticated fault management is available for
the advanced user.
The commands associated with Fault management are listed below.
FM TYPES
Provides a complete list of all faults defined in the
unit. Included is a description and activation status.
•
See below for a sample of the Fault Types
display. Your specific display will vary
based on purchased options and software
revision.
•
The Fault ID is a numeric code assigned
to the fault
•
Activated – normally all faults are
activated. De-activating a fault will cause
that fault to be ignored.
•
Triggers relay – describes whether or not
that particular fault drives the fault relay.
•
Description of the fault.
FM EN_FLT
The user enters FM en_flt xx where xx is the Fault
ID to enable that fault
FM EN_FLT
The user enters FM dis_flt xx where xx is the Fault
ID to disable that fault
>fm types
This are the Fault Types for the HE400:
Fault id , Activated?, Triggers Relay?, Description:
--------------------------------------------------------------------------------
6-10