Table Top/Rack Mount Installation Instructions
HE4000 Encoding System
The 1U unit contains 8 screws in the shipping kit. One side of each
bracket has four small holes while the other side has two large holes.
2.
Attach the brackets to both sides of the unit:
a.
Line up the small holes on the bracket with the unit’s mounting holes, which are
located towards the front of each side panel.
b.
Thread all of the screws through the bracket’s small holes and into the
ComtechTV unit. The screws should be flush with the bracket when tightened.
3.
Mount the unit in the rack by attaching the front brackets to the rack using your own
washers and bolts.
4.
Ensure that the installation provides the minimum required air flow clearances at the
sides and rear of the unit.
D.2 Safety Precautions
If rack-mounted units are installed in a closed or multi-unit rack, consider the following items;
further evaluation by a Certifying Agency may be required.
D.3 Ambient Temperature
The ambient temperature within the rack may be greater than the room’s ambient temperature.
When installing the unit, ensure that the required air flow for safe operation is provided. Never
restrict air flow through the unit’s fans or vents.
D.4 Rack Stability
During installation, consider weight distribution on the rack; hazardous stability conditions may
arise if units are loaded into the rack unevenly.
D-2
01-0951-404 Rev B