HE4000 Encoding System
Using a Remote Unit
HE4000 Remote Command Descriptions
Remote Command
Parameter
Range
Factory
Default
Description
AC3mixlev
AE.<
port
>
AC3ROOM
NI, SM, LG
SM
AC3 Room size descriptor
AE.<
port
>
AC3DCFIL
ON, OFF
ON
AC3 DC Filter enable
AE.<
port
> AC3LPFIL
ON, OFF
ON
AC3 Low Pass Filter enable
AE.<
port
>
AC3PRFIL
ON, OFF
OFF
AC3 Protection Filter enable
AE.<
port
>
AC3BMOD
32, 16L, 16R
32
AC3 Pass- through Bit mode
32 bit
16 bit left
16bit right
AE.<
port
>
AC3STRMN
0 - 7
0
AC3 Stream Number
AE.<
port
>
AC3PREAM
ON, OFF
ON
AC3 Preamble enable
AXD.A BAUD
1200, 2400,
4800, 9600,
19200, 38400
bps
38400 bps
Sets the asynchronous serial auxiliary data baud
rate.
AXD. <port>
BELONG2
SD, HD
HD
Designates the auxiliary data as being associated
with HD or SD
AXD.B DR
1200 to
20,000,000
bps
1024000
bps
Sets the data rate for the synchronous auxiliary
data channel.
Note: The data rate for the auxiliary data
channel reduces the total transport stream bit
rate available for the video signal; therefore, an
auxiliary data rate should be selected that
meets but does not exceed the site-specific
operational requirements.
AXD.<
port
> EN
Off, On
Off
Enables or disables the auxiliary data channel in
the transport stream. Parameters are:
● Off = auxiliary data is not included in the
transport stream
●
On = auxiliary data is included in the
transport stream.
AXD.A PARITY
N, O, E
N
Sets the parity bit for asynchronous serial
communication. Parameters are:
N = none, O = odd, E = even.
AXD.B SRC
INT, EXT
INT
Sets the clock source for the synchronous auxiliary
data channel; parameters are:
● INT = internal, uses ST to latch the data.
● EXT = external, uses TT to
latch the data.
AXD SRC is only available when AXD Mode
is set to sync.
AXD.A STOP
1, 2
1
Sets the number of stop bits for the asynchronous
serial protocol.
AXD.A WIDTH
7,8
8
Sets the number of data bits for asynchronous
serial data.
AXD.A FC
NONE, HARD
None
Sets the flow control for asynchronous serial
data.
CA BISS1 ENABLE
Off, On
Off
Enables BISS conditional access. Only available if
the BISS feature has been purchased.
CA BISS1 KEY
0 to
FFFFFFFFFF
FF (hex)
0
Used for entry of the BISS mode 1 key. Key may
be any numeric entry (hex) up to 12 characters in