MC RE
-
-
Resets the HE4000, reloads all programmable
logic and firmware, and restarts the system. All
parameters return to the last settings stored in flash
memory or the last changes made using the front
panel. The HE4000 restores configuration settings
as follows:
● All changes made using the front panel are
automatically stored in flash memory. When
the HE4000 is reset, any changes made
using the front panel are restored.
● Changes made using a remote unit are not
automatically stored in flash memory. If the
HE4000 is reset before issuing the CM SAVE
command, changes made using a remote unit
are not restored. Instead, the last changes
saved to flash memory are restored.
● If the HE4000 configuration is changed using
a remote unit, an operational test should be
performed to verify system operations. Then
the new configuration should be saved by
issuing the CM SAVE command. Once the
configuration is saved, the HE4000
automatically restores the saved settings
when the unit is reset or powered up.
Note: The HE4000 real- time clock includes a
battery backup source. If the unit loses power,
is turned off, or reset, the real-time clock
reverts to the current day and time. This
backup power will only last for approximately
one week.
01-0951-404 Rev B
4-19