leakage of harmful substances.
• Connect the control unit exclusively to an electric power supply line equipped with an efficient protective earth conductor.
• Any operations that require the housing of RAMPART to be opened must be performed with the control unit disconnected from
the electrical power supply; if the disconnect device is not clearly visible from where you are working, attach a warning notice to
the effect: "WARNING - MAINTENANCE IN PROGRESS”.
• In the case of tripping of circuit breakers or blowing of fuses, find the fault and remedy it before resetting the circuit breaker or
changing the fuse.
• If the fault cannot be remedied using the information given in this manual, consult technical service.
• The device can’t be used by children younger than 8 years of age and by people with reduced physical, sensory or mental
capabilities, or without experience or the required knowledge if not under surveillance or after having received instructions about
the safe use of the device and the inherent risks in it. Children should not play with the device. Cleaning and maintenance should
not be carried out by children without surveillance.
• Children can’t play with the commands of the automatism. Remote controls should be kept out of reach of children. It is suggested
to periodically examine the installation in order to verify the presence of possible damages to the cables, springs and mechanical
parts. Automation should not be used if it is necessary a repair intervention.
2 MODELS AND PRODUCTS DESCRIPTION
2.1 DESCRIPTION
Electromechanical operator for spring balanced sectional doors. Operator designed for coupling to tracks with a drive belt or chain,
built-in electronic control unit with electronic limit stops (encoder) for 24V motor, plug-in radio receiver: 433.92 MHz narrowband.
2.2 TYPICAL INSTALLATION
C
D
B
A
KEY
A OPERATOR WITH BUILT-IN CONTROL UNIT
B CLOSING PHOTOCELLS
C FLASHING LIGHT
D KEY SELECTOR SWITCH
3 TECHNICAL SPECIFICATIONS
RAMPART 600
RAMPART 1000
Power
230V (±10%) / 50Hz
Maximum pulling effort (force needed to start door move)
600N
1000N
Nominal pulling effort (force needed to maintain door move)
200N
300N
Maximum door leaf weight
110kg
210kg
Maximum opening speed
0,14 meters/seconds
Speed during nominal effort
0,1 meters/seconds
Maximum continuous motortime
60 seconds (intermittent operation mode)
Power consumption during nominal effort
110 W
150 W
Light time (LED-time) after movement stop
30 seconds after opening the door
1 minute after closing the door
Current consumption of additional (external devices)
24V DC / max. 8W (max 300mA)
Current consumption of external signal Lamp
24V DC / max. 5W (max 200mA)
Radiocontrol
433,92MHz / dynamic code
200 remotes max
Protection type
II
Protection class
IP20
Temperature range
-20°C / +50°C
Drive weight (net)
4,5kg
5,0kg
Summary of Contents for RAMPART 1000
Page 2: ...2 COMUNELLO Copyright 2021 All rights reserved FIG 1 FIG 2 40 400 0 400 2800 mm 500 mm...
Page 3: ...3 COMUNELLO Copyright 2021 All rights reserved FIG 3 FIG 5 FIG 6 FIG 4...
Page 4: ...4 COMUNELLO Copyright 2021 All rights reserved FIG 8 A FIG 7 FIG 9 FIG 11 FIG 10 FIG 10...
Page 5: ...5 COMUNELLO Copyright 2021 All rights reserved FIG 14 FIG 12 FIG 13 FIG 15...
Page 6: ...6 COMUNELLO Copyright 2021 All rights reserved FIG 16 FIG 17 FIG 18...
Page 50: ...NOTES...
Page 51: ...51 COMUNELLO Copyright 2021 All rights reserved NOTES...