PRESCRIPTIONS

•  The control unit is not equipped with a device for 

disconnection of the 230 V~ power supply line. 

It is therefore the responsibility of the installer 

to fit a disconnection device in the electrical 

system. The disconnection device must be 

composed of a category III overvoltage all-pole 

circuit breaker. This device must be positioned 

in consideration of the need to be protected 

against inadvertent reconnection in compliance 

with the requirements of EN 12453 point 5.2.9. 

Wiring of the external electrical devices to the 

control unit must be carried out in compliance 

with the prescriptions of EN 60204-1 as 

amended by EN 12453 point 5.2.7. The 

maximum diameter of power feeding cables is 

14 mm; fixing of power feeding and connection 

cables must be assured by fitting cable glands, 

which can be supplied as optionals.

• The power input cables must be of the 

standardized flexible type with polychloroprene 

sheath (H05RN-F) having minimum conductor 

size of 1 mm

2

.

• During the installation operations, take care to 

use cable with double insulation only (sheathed 

cables) for both of mains voltage connections 

(230V) and extra-low voltage connections 

(SELV). Use exclusively plastic cable trays, 

separated for mains voltage wiring (230V) and 

extra-low voltage wiring (SELV).

• The extra low voltage conductors must be 

physically separated (at least 4 mm in air) from 

the mains voltage wires, or shall be adequately 

insulated with extra insulation with a thickness 

of at least 1 mm.

• Upstream of main supply, install a device that 

ensures the complete omnipolar disconnection 

(cut-off switch) of the power supply, with a 

contact opening gap of at least 3mm in each 

pole. These disconnecting devices shall be 

places in the power supply wiring in compliance 

with the installation standards and must be 

directly connected to the supply terminals.

•  When drilling the outer case to insert the power 

and connection cables and when fitting the 

cable glands, take care to install all the parts 

in a manner that maintains the IP protection 

characteristics of the box unchanged as far 

as possible. Ensure the cables are fixed in a 

stable and secure manner.

•  The rear of the box is equipped with knockouts 

for wall fixing (knockouts for fixing holes using 

anchor bolts or holes for fixing with screws). 

Take all the measures required to ensure the 

installation procedures do not affect the IP 

rating.

• If required, a pushbutton panel for manual 

control of the gate must be installed in a position 

such as to ensure the user is not placed in 

danger.

• The operator utilized to move the gate must 

be in compliance with the prescriptions of EN 

12453, point 5.2.7.

•  Power Supply output D.S. must be used for 

photocells. Alternative uses of this output are 

not permitted.

• At each operating cycle, the control unit 

can test the photocells operation to ensure 

protection against failure of anti-crushing 

protective devices according to Category 2 in 

compliance with the prescriptions of EN 12453 

point 5.1.1.6. It follows that if the safety devices 

are not connected or are faulty, operation of 

the control unit will be inhibited.

• The device can be used by children no older 

than 8 years old and people with reduced 

physical, sensory or mental capabilities, or 

lack of experience or without the required 

knowledge, but only under surveillance or after 

having received instructions about the safe 

use of the device and the hazards inherent in 

it. Children should not play with the device. 

Cleaning and maintenance should not be 

carried out by children without supervision. 

For correct operation of the radio receiver section, 

when using two or more control units it is good 

practice to install them at a minimum distance of 

3 metres from one another.

All operations that require the control unit box to 

be opened (connection of cables, programming, 

etc.) must be carried out by expert personnel at 

the time of installation. For all further operations 

that require the box to be re-opened.

IMPORTANT INFORMATION FOR USERS

• The device must not be used by minors or 

psychologically-physically differently abled 

persons unless they are supervised or duly 

instructed on the operation and methods of 

use.

• Do not let children play with the device and 

keep the remotes out of their reach.

• 

IMPORTANT:

 keep this instruction manual and 

comply with the safety prescriptions set down 

herein. Failure to comply with the prescriptions 

may cause damage and serious accidents.

Frequently examine the system to identify any 

signs of damage. Do not use the device if repairs 

are required.

Summary of Contents for CU-24V-1M

Page 1: ...USER S MANUAL Control unit comunello com ISTRUZIONI D USO E DI INSTALLAZIONE INSTALLATIONS UND GEBRAUCHSANLEITUNG INSTRUCIONS D UTILISATION ET D INSTALLATION INSTRUCCIONES DE USO Y DE INSTALACION Cod...

Page 2: ...ON OFF L5 RELEASE STROKE ON OFF L6 SLAM LOCK ON OFF L7 COURTESY LIGHT ON OFF LEV LEV 1 FLASH ID LED L1 SOFT STOP ON OFF L2 SOFT START ON OFF L3 DS 1 IN OPEN ON OFF L4 HOLD TO RUN ON OFF L5 FOLLOW ME...

Page 3: ...C 24V SLIDING GATE CU 24V 1M ID Description Cable type Lenght 1m to 20m Lenght 20m to 50m 1 Main power supply FG7 CEI 20 22 CEI EN 50267 2 1 2x1 5mm2 2x2 5mm2 2 Flashing light 2x0 5mm2 2x1 0mm2 4A 6A...

Page 4: ...RSA CHIUDI N C END CLOSE N C FOTOCELLULA DS N C ATTIVA IN CHIUSURA PHOTCELL DS N C ACTIVE IN CLOSING FOT GND STOP GND GND FCA DS1 GND PP ANT ANT FCC CN2 LAMPEGGIANTE FLASHING LIGHT 24V 4W CN1 M MOTORE...

Page 5: ...reserved ITALIANO FORT like below Led opening direction OFF OPENS TO THE RIGHT Inner side view OPENING DIRECTION 1 MOTOR CONFIGURATION FORT FORT like below Led opening direction ON OPENS TO THE LEFT I...

Page 6: ...SALIENT DO NOT CHANGE the configuration Opens to the left closes to the right left profile view as in the image SALIENT BLACK ON M1 RED ON M1...

Page 7: ...directives 2004 108 EC Directive EMC Directive 2006 95 CE Directive and that all the rules and or technical specifications shown below have been applied EN61000 6 2 EN61000 6 3 EN62233 2008 EN301489 1...

Page 8: ...The rear of the box is equipped with knockouts for wall fixing knockouts for fixing holes using anchor bolts or holes for fixing with screws Take all the measures required to ensure the installation p...

Page 9: ...ttons are used to control the gate operation is as follows the first command opens the gate until motor time or until the gate reaches its opening limit position the second command closes the gate if...

Page 10: ...the latter will be controlled thus effectively relinquishing the security of the rolling code system 4 CONDO The Condominium function means that during the opening movement or during the pause time th...

Page 11: ...become steady on and programming will be completed Repeat the procedure if you wish to restore the previous configuration 2 PED MOT T Programming of pedestrian opening motor time of max 4 minutes The...

Page 12: ...upward each additional LED corresponds to a higher power level Use the SEL key to scroll through the different power levels for each selected power level the top LED will blink for example selecting l...

Page 13: ...FRATELLI COMUNELLO S P A AUTOMATION GATE DIVISION Via Cassola 64 C P 79 36027 Ros Vicenza Italy Tel 39 0424 585111 Fax 39 0424 533417 info comunello it www comunello com...

Reviews: