background image

IP CAMERA QUICK START GUIDE

4. Finding the Camera IP Address

Using the Analogue Service Video Output (SVO)

When the analogue SVO cable is connected to the camera, the camera IP address is 
displayed on the CVBS video displayed on a test monitor. The camera must be powered on 
to use the SVO feature.

Using the IPSearch Windows Software

IPSearch can be found on the included CD. Connect a PC to the same network as 
the IP camera, insert the CD into the PC, locate and open IPSearch.

When IPSearch loads, press Start to scan 
the network for any connected IP cameras. 
Located cameras can be sorted by IP 
address, model name, or firmware version.

Use the listed IP address to access the camera 
via Internet Explorer.

When prompted, install the ActiveX controls 
for the best remote web viewing experience. 
The default user name is admin and the 
default password is admin.

Note: After first logging in to the IP camera, 
you will be prompted to change the default 
password to a secure password. This is highly 
recommended for all users to ensure proper 
device security.

Using the Concept Pro Test Monitor (VLEDTM-TS7)

Turn on the VLEDTM-TS7 test monitor and enter 
the IP Camera menu, then select ONVIF.

ONVIF will open and automatically scan the 
connected network for ONVIF devices.  
The test monitor can connect via WiFi or wired 
LAN connection to the same network  
as the IP camera.

Using Bonjour® on Mac OSX®

1. Open the Safari® web browser on the Mac 
and click the Bookmarks button.

2. Select Bonjour. The camera IP address will 
appear in the Bonjour Devices list.

3. Double-click the camera to open in Safari.

Summary of Contents for CVP9324DN-IP

Page 1: ...CVP9324DN IP CVP9324DNIR IP CVP9324DN IP4M CVP9324DNIR IP4M CVP9324DNIR IP4M G CVP9324DNIR IP4M Z IP External Dome Camera QUICK START GUIDE IP CAMERA QUICK START GUIDE ...

Page 2: ... mark and pre drill the required holes Remove two of the three base locking screws Use two of the 2 8 screws to mount the camera directly to the mounting surface Then remove the third base locking screw and install the final 3 8 screw Position the lens module in the desired configuration then replace the dome cover Surface Mount Method 2 Use the included mounting template option 1 to mark and pre ...

Page 3: ...ply requirements specified and connect to the camera DC12V power input Connect the RJ45 connector to a network switch If the network switch supports Power over Ethernet PoE disconnect any DC12V power connections View the image on a monitoring device such as a BNC test monitor to confirm the power and video connections are properly working Inner Camera Connections Reset Button Analogue Service Vide...

Page 4: ...rnet Explorer When prompted install the ActiveX controls for the best remote web viewing experience The default user name is admin and the default password is admin Note After first logging in to the IP camera you will be prompted to change the default password to a secure password This is highly recommended for all users to ensure proper device security Using the Concept Pro Test Monitor VLEDTM T...

Page 5: ...cal IP address See steps above Verify the camera s local IP address using one of the methods listed in Finding the Camera IP Address Can t connect to camera on a web browser using a DDNS address Port forwarding not set up Make sure the HTTP port default 80 and Control port default 30001 are forwarded on your router to the camera local IP address Multiple cameras using same port number to connect C...

Page 6: ...g conditions Severe lighting change or flicker can cause the camera to work improperly 6 Never use the camera close to a gas or oil leak 7 Do not disassemble the camera 8 Never let the camera directly face a strong light source 9 Ensure all removable covers are replaced to protect the inner components 10 Do not install near devices which emit a strong electro magnetic field 11 Use a dry or damp cl...

Page 7: ...Z models are ideal for Number Plate Capture installations Simply follow the instructions below to configure the settings for Number Plate Capture 1 Connect the Concept Pro IP camera to a PoE switch and PC Navigate to the IP camera web interface 2 From the live video stream right click the video and select Sensor ...

Page 8: ...left 4 Select the Exposure tab and apply the following settings Mode Manual Meter Area Whole Fix Shutter 1 20000 Fixed Gain 50 Iris Auto Iris Speed 50 This setting may require adjusting depending on the installation environment Please be sure to test and just settings for optimal performance ...

Page 9: ...gth 50 This setting may require adjusting depending on the installation environment Please be sure to test and just settings for optimal performance 6 Select the Enhance Image tab and apply the following settings HLC On 100 Anti shake On 7 Click Save then Yes Switch from Debug Mode back to Standard Mode and close the window ...

Page 10: ...IP CAMERA QUICK START GUIDE NOTES ...

Page 11: ...IP CAMERA QUICK START GUIDE NOTES ...

Page 12: ...Design and specification are subject to change without notice ...

Reviews: