Common Issues Answered

Can’t find the camera IP address using Concept Pro Lite or other software:
•  Make sure Ethernet and/or DC power cables are correctly connected to the camera.
•  Make sure the PoE switch or DC power source meets the camera power requirements.  

If using PoE, make sure the PoE switch is powered on.

•  Make sure the PC is on the same network as the camera. Ping the camera’s IP address. 

On your PC, go to Start>Programs>Accessories >Command Prompt. Type ping then the 
camera’s local IP address and press Enter. If you get the message “Request timed out,” 
PC and camera are not on the same network or camera is not connected. Camera is 
connected if you receive replies.

•  Connect the BNC test cable to the camera and the other end to a test monitor. The 

monitor display shows the camera’s IP address. A default IP address of 192.168.0.120 may 
mean that the camera cannot obtain an IP address from the router. Check the Ethernet/
power connections and router configuration.

•  Camera set for static IP mode using an incorrect IP address. By default, the camera is set 

for DHCP mode, which means it will automatically obtain an IP address from your router. 
Reset the camera to factory default settings by removing the camera dome cover and 
pressing the reset button for 5 seconds or more.

Can’t connect to the camera on a web browser using local IP address:
•  See steps above.
•  Verify the camera’s local IP address using one of the methods listed in  

“Finding the Camera IP Address.”

Can’t connect to camera on a web browser using a DDNS address:
•  Port forwarding not set up. Make sure the HTTP port (default: 80) and Control port  

(default: 30001) are forwarded on your router to the camera local IP address.

•  Multiple cameras using same port number to connect. Configure each camera to use 

different ports and port forward the new ports.

•  DNS servers not set correctly in the camera network settings
•  If DHCP is enabled on the camera and connected to an NVR, the NVR will configure the 

default settings of the camera.

Can’t connect to camera video on a web browser:
•  If using IE, make sure to install ActiveX plug-in or Adobe Flash Player.
•  If using a browser other than IE. (e.g. Google Chrome, Apple Safari, Mozilla Firefox), make 

sure the latest version of Adobe Flash Player is installed.

Video performs poorly on browser:
•  Insufficient bandwidth available for high-quality stream1. Select stream 2 under Stream. 

Stream 2 provides a lower resolution to conserve bandwidth and improve performance on 
low-bandwidth connections.

•  If using IE, click the message above the video area to use ActiveX plug-in instead of Flash 

Player. ActiveX may provide smoother video performance.

User account is locked:
•  User accounts are locked when the password has been incorrectly entered 3 Times. 

To unlock the account, login to the camera web interface as admin. Click Privilege 
Manager>User. Under User, select the locked user account and click Unlock to unlock the 
account.

Summary of Contents for CVP9324DN-IP

Page 1: ...CVP9324DN IP CVP9324DNIR IP CVP9324DN IP4M CVP9324DNIR IP4M CVP9324DNIR IP4M G CVP9324DNIR IP4M Z IP External Dome Camera QUICK START GUIDE IP CAMERA QUICK START GUIDE ...

Page 2: ... mark and pre drill the required holes Remove two of the three base locking screws Use two of the 2 8 screws to mount the camera directly to the mounting surface Then remove the third base locking screw and install the final 3 8 screw Position the lens module in the desired configuration then replace the dome cover Surface Mount Method 2 Use the included mounting template option 1 to mark and pre ...

Page 3: ...ply requirements specified and connect to the camera DC12V power input Connect the RJ45 connector to a network switch If the network switch supports Power over Ethernet PoE disconnect any DC12V power connections View the image on a monitoring device such as a BNC test monitor to confirm the power and video connections are properly working Inner Camera Connections Reset Button Analogue Service Vide...

Page 4: ...rnet Explorer When prompted install the ActiveX controls for the best remote web viewing experience The default user name is admin and the default password is admin Note After first logging in to the IP camera you will be prompted to change the default password to a secure password This is highly recommended for all users to ensure proper device security Using the Concept Pro Test Monitor VLEDTM T...

Page 5: ...cal IP address See steps above Verify the camera s local IP address using one of the methods listed in Finding the Camera IP Address Can t connect to camera on a web browser using a DDNS address Port forwarding not set up Make sure the HTTP port default 80 and Control port default 30001 are forwarded on your router to the camera local IP address Multiple cameras using same port number to connect C...

Page 6: ...g conditions Severe lighting change or flicker can cause the camera to work improperly 6 Never use the camera close to a gas or oil leak 7 Do not disassemble the camera 8 Never let the camera directly face a strong light source 9 Ensure all removable covers are replaced to protect the inner components 10 Do not install near devices which emit a strong electro magnetic field 11 Use a dry or damp cl...

Page 7: ...Z models are ideal for Number Plate Capture installations Simply follow the instructions below to configure the settings for Number Plate Capture 1 Connect the Concept Pro IP camera to a PoE switch and PC Navigate to the IP camera web interface 2 From the live video stream right click the video and select Sensor ...

Page 8: ...left 4 Select the Exposure tab and apply the following settings Mode Manual Meter Area Whole Fix Shutter 1 20000 Fixed Gain 50 Iris Auto Iris Speed 50 This setting may require adjusting depending on the installation environment Please be sure to test and just settings for optimal performance ...

Page 9: ...gth 50 This setting may require adjusting depending on the installation environment Please be sure to test and just settings for optimal performance 6 Select the Enhance Image tab and apply the following settings HLC On 100 Anti shake On 7 Click Save then Yes Switch from Debug Mode back to Standard Mode and close the window ...

Page 10: ...IP CAMERA QUICK START GUIDE NOTES ...

Page 11: ...IP CAMERA QUICK START GUIDE NOTES ...

Page 12: ...Design and specification are subject to change without notice ...

Reviews: