21
EN
CA1020
PRODUCT DESCRIPTION
1
Display
2
Air outlet cover
3
Upper part of the body
4
Decorative ring
5
Bottom part of the body
6
Filter
7
Appliance base
8
UVC
INSTALLING THE FILTER
•
Turn the filter base counterclockwise (Fig. 1).
•
Insert the filter.
•
Insert the base back and turn it clockwise.
USE
TIMER:
When the appliance is running, the operating time can be set using the “timer” button. Set the time to 2 hours, 4 hours, 8 hours, press again to turn off,
the corresponding indicator lights up after the selected time.
Fan speed:
Press the fan speed button to change the speed (1-3) and select automatic mode.
Automatic mode:
Press the fan speed button to select the fan speed A. The appliance will automatically change the fan speed according to the ambient contaminants.
RESET:
The appliance is equipped with a filter replacement alert function. When the filter replacement indicator lights up, replace the filters. Then hold the
button for 3 seconds and the countdown will reset.
INSTALLATION INSTRUCTIONS
•
In case of internal dust, such as pollen, the appliance should be placed on the ground. Since pollen, dust, etc. are usually held close to the floor, it is
recommended to place the purifier on a flat floor in the room.
•
In order not to block the air inlet and outlet, place the appliance about 30 cm or more away from the left and right sides of the wall, furniture, curtains,
etc. For effective use of the appliance, please keep it at least 20 cm away from the wall behind it.
•
Do not place any objects on the top of the appliance (this may cause the appliance to malfunction).
•
Note: Do not place magnets or metal objects on the appliance.
•
Do not block the air inlet and outlet, for example, do not place any objects on the air outlet. Or on the front side, on the air inlet.
MAINTENANCE
Disconnect the mains supply before cleaning and maintenance.
•
Place the filter in a ventilated area so that harmful gases and bacteria on the filter surface can evaporate. Do not expose it to excessive sunlight.
•
Do not wash the filter with water.
•
Do not work with the filter removed (operation without the effect of removing dust may cause the appliance to malfunction).
•
If the appliance is idle for a long time, unplug the power cord (it also consumes power in standby mode).
UVC lamp replacement
•
Turn the bottom cover counterclockwise to remove it (Fig. 1).
•
Remove the filter.
•
Pull the UVC lamp up to remove it and replace it with a new one (Fig. 2).
•
Carry out the procedure in reverse to reassemble the appliance.
TROUBLESHOOTING
Common faults, error code description and troubleshooting method.
Problem
Cause
Remedy
It is not possible to turn on or press the
button, no response
Is the power cord plugged in?
Plug in the power cord.
The odour from the appliance outlet is
unpleasant
Is the filter installed correctly?
Follow the installation instructions and
precautions.
The purifier runs for a long time, but the air
quality does not improve significantly
The filter indicator is on: this means that the
filter replacement timer has reached the
set value.
After replacing the filter, press the button to restart
the filter.
Control panel
A
UV on/off
B
Night mode
C
Fan speed
D
Wi-Fi symbol
E
On/off button
F
Timer
G
Filter restart