48
EN
OPI3075
Carbon filter (to be purchased)
This filter is only used for the recirculation mode.
The filter contains an active carbon absorbing the smell being discharged. The active carbon will be saturated after
some time, hence the absorption capacity will be shortened. This filter cannot be washed or cleaned in any other way.
When the appliance is in common use, the carbon filter should be replaced every 2-3 months. In case of more frequent
frying or deep frying, shorten this interval.
1. Remove the metal filters as shown in Fig. 1.
2. The carbon filters are situated on both sides of the motor. Turn the filters, until they are secured (see Fig. 2).
3. To replace the carbon filter, proceed in reverse order.
INSTALLATION OF THE APPLIANCE
Caution!
Risk of electric shock! Before installation, disconnect the power cord from the wall outlet. Otherwise there is a risk of
death or electric shock.
• Defects caused by improper installation are not covered by the warranty.
•
Installation is the responsibility of the customer not the manufacturer.
•
The manufacturer bears no responsibility for damage caused to people, animals or property due to incorrect
installation.
•
All guards must be placed firmly in their appropriate place in a way they cannot be removed without using special
tools.
•
Install the appliance at least
500 mm
over electric cookers or electric cooking plates and at least
500 mm
over gas
cookers or gas cooking plates.
•
Extracted air should not be led to a chimney intended for discharge of flue gases and combustion products or
a shaft serving for ventilation of rooms where fireplaces are situated.
•
Any bend of the ventilation pipe should be ≥120°.
•
The room must be well ventilated during cooking.
Connection to the mains
•
Make sure the mains voltage and current protection correspond to the values on the rating plate of the appliance.
•
Only use grounded sockets.
•
Do not use multiple sockets, plugs and extension cords.
•
The plug of the power cord on the appliance must be freely accessible even after the installation.
Fig. 2
Opened
Closed
Opened
Closed
Summary of Contents for OPI3075
Page 2: ...2 OPI3075 CZ ...
Page 39: ...39 LV OPI3075 Ierīces izmēri 285 725 10 750 710 296 271 86 246 Ø150 ...
Page 53: ......