English
1.
Power LED Indicator
(
) :
Green LED remains standstill when Utility is normal.
Green LED flashes every 3 seconds and simultaneously buzzer
alarms continuously when Utility failure.
Green LED flashes every 3 seconds when the UPS is in Battery
charging mode.
Green LED remains standstill and simultaneously buzzer alarms
continuously when the UPS is in overload condition.
2.
Battery LED Indicator
(
) :
Red LED flashes every 0.5 seconds and buzzer alarms every 0.5
seconds when UPS is in battery low condition.
3.
Power ON / OFF
:
To Control on/off the UPS when Utility is normal.
To enable “DC-Start” Function when Utility fails. (To enable DC Start
properly, you are recommended to connect <80% output load with
the UPS only)
Note
:
Make sure the computer connected to the UPS is switched on
before enable the "DC-Start" function. You are not recommended
to add some other computer or peripherals after DC-Start function
is activated. pK3GrJzs