TROUBLESHOOTING
Symptom
Possible Cause
Possible Solution
No display or status lights.
No power to the system.
Check that the power source is live.
Power connections came loose from
electronic control board.
Restore power.
Restore power connections to
electronic control board
Replace electronic control board.
The pressure readings are
incorrect on the system
display.
Transducer is not properly calibrated
Transducer connection came loose from
the electronic control board
Transducer cable is damaged
Transducer is not working properly
Recalibrate the transducer using the
Ch Offset option under the System
menu
Restore transducer connections to
electronic control board
Replace transducer cable
Replace transducer
Replace electronic control board
There pressure switch status
is not displaying properly
Pressure switch connection came loose
Pressure switch is damaged
Restore pressure switch connections
Replace pressure switch
Replace electronic control board
Output relays not
functioning
Remote monitoring system is not
powered.
Wiring between the Altos 2™ output
relays and the remote monitoring system
is not correct.
Check that the remote system is
powered on
Check wiring between Altos 2™
output relays and remote monitoring
system.