TROUBLESHOOTING

 

Symptom

 

Possible Cause

 

Possible Solution

 

No display or status lights. 

 

No power to the system. 

 

Check that the power source is live. 

 

Power connections came loose from 
electronic control board. 
 
 

 

Restore power.  

 

Restore power connections to 
electronic control board 

 

Replace electronic control board.  

 

The pressure readings are 
incorrect on the system 
display. 

 

Transducer is not properly calibrated 

 

Transducer connection came loose from 
the electronic control board 

 

Transducer cable is damaged 

 

Transducer is not working properly 

 

 

Recalibrate the transducer using the 
Ch Offset option under the System 
menu 

 

Restore transducer connections to 
electronic control board 

 

Replace transducer cable 

 

Replace transducer 

 

Replace electronic control board 

 

There pressure switch status 
is not displaying properly 

 

Pressure switch connection came loose 

 

Pressure switch is damaged 

 

 

Restore pressure switch connections 

 

Replace pressure switch 

 

Replace electronic control board 

 

Output relays not 
functioning  

 

Remote monitoring system is not 
powered.  

 

Wiring between the Altos 2™ output 
relays and the remote monitoring system 
is not correct.  

 

 

Check that the remote system is 
powered on 

 

Check wiring between Altos 2™ 
output relays and remote monitoring 
system. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Altos 2

Page 1: ...TING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 422...

Page 2: ...IRONMENTS DO NOT INSTALL THIS PRODUCT IN ANY HAZARDOUS ENVIRONMENT If product appears damaged in any way do not use and request service from CONCOA USER RESPONSIBILITY Service to this product should o...

Page 3: ...arm Outputs 16 Muting Audible Alarm 16 Configuration using the LCD Screen 17 Status Menu 18 Channel Settings 19 Input Alarm Mode 20 Alarm Set Point 21 Units of Measure 22 Alarm Settings 22 Alarm Delay...

Page 4: ...e displayed locally on a 2 57 LCD screen for up to 2 channels The statuses of all inputs are also displayed locally with high visibility multicolor LEDs that turn red when an input exits its normal co...

Page 5: ...t panel which is laid out with two status lights representing channels 1 and 2 The indicator lights are bi colored LEDs so that the same light can be turned ON as either a green indicator or a red ind...

Page 6: ...from the external inputs to determine the state of the alarms The normal conditions of these alarms are customizable via the configuration menu If there are no alarm conditions the Altos 2 will turn...

Page 7: ...act inputs depending on the channel configuration The external device wires 12Vdc out signal in are brought in through a conduit connector on the left side of the box and connected to terminal blocks...

Page 8: ...6 Figure 3...

Page 9: ...523 Switchovers Only J2 2 Channel 2 LED Driver for 522 523 Switchovers Only J2 3 Ground Terminal Function J5 1 Channel 1 Normally Closed Relay Output J5 2 Channel 1 Relay Common J5 3 Channel 1 Normall...

Page 10: ...8 Figure 4 Figure 5 Figure 6...

Page 11: ...9 Figure 7...

Page 12: ...10 Figure 8 Figure 9...

Page 13: ...11 Figure 10...

Page 14: ...12 Figure 11...

Page 15: ...13 Figure 12 Figure 13...

Page 16: ...14 Figure 14 Figure 15...

Page 17: ...uge AutoSwitches with Pressure Switch Gauges Dual Regulator Switchovers with Pressure Switch Gauges Alarm to Intrinsic Safety Barriers 538 544 642 643 Series IntelliSwitch IIs CONCOA Cable Ass y Part...

Page 18: ...output cable assembly is 14 26 AWG The length of each cable should be limited to 1500 feet After cutting the cable to length remove the outer jacket to expose approximately 3 4 inch of the internal c...

Page 19: ...s and configuration of the system The Altos 2 LCD screen displays system status by default Figure 16 The Altos 2 Settings Menu is also displayed via the LCD screen Pressing any navigation button on th...

Page 20: ...he navigation buttons when the keypad is locked will cause the Altos 2 to display a keypad lock out warning for a couple of seconds before returning to the display screen SETTINGS MENU The Altos 2 Set...

Page 21: ...19 CHANNEL SETTINGS The Channel Settings Menus Channel 1 and Channel 2 contain three settings for each channel Input Alarm Mode Alarm Set Point and Units of Measure Figure 19...

Page 22: ...fied channel to use the transducer input and causes the channel to alarm when the measured pressure falls below the alarm set point see Alarm Set Point section Switch Closed Configures the specified c...

Page 23: ...re 21 Pressing up or down on a particular digit will modify only the selected digit To navigate between digits press left or right To save the selected setting navigate to the far right digit and pres...

Page 24: ...e determines BAR PSI or kPa Altos 2 will display the selection for the specified channel The default setting is PSI Figure 22 ALARM SETTINGS The Alarm Configuration menu contains two global alarm choi...

Page 25: ...it and press right again The Altos 2 will not allow the user to select a value outside the maximum and minimum values displayed The default value for this setting is 0 minutes Pressing up or down on a...

Page 26: ...24 Blink When Both In Alarm Blink When Both in Alarm causes the red alarm LEDs to blink when both channels are in alarm The default setting is OFF Figure 25...

Page 27: ...System Configuration menus contain twelve settings Set Ch1 Offset Set Ch2 Offset Set Ch1 Max Set Ch2 Max Deadband Ch1 Deadband Ch2 Audible Mode Power Save Mode Keypad Lockout Test Mode Reset and Abou...

Page 28: ...s than the maximum transducer pressure rating Pressing up or down on a particular digit will modify only the selected digit To navigate between digits press left or right To save the selected setting...

Page 29: ...on a particular digit will modify only the selected digit To navigate between digits press left or right To save the selected setting navigate to the far right digit and press right again The default...

Page 30: ...n the Input Alarm Condition Figure 30 Pressing up or down on a particular digit will modify only the selected digit To navigate between digits press left or right To save the selected setting navigate...

Page 31: ...vides instructions on how to change the audible mode Default is ON Figure 31 WARNING If audible mode is enabled each navigational button press results in a chirping sound If audible mode is disabled t...

Page 32: ...enabled turns off the LCD screen after fifteen minutes of inactivity When the screen is off the unit will still alarm as normal Pressing any button on the front cover will wake the unit up when in po...

Page 33: ...lt Mode is OFF Figure 33 Test Mode Test Mode provides instructions for enabling Test Mode Test Mode toggles all LED s speakers and relays as well as displays the Altos logo to test proper operation of...

Page 34: ...Activating Reset restores all parameters to the factory default state and resets the device Figure 35 About The about screen displays the system part number as well as the installed software version F...

Page 35: ...working properly Recalibrate the transducer using the Ch Offset option under the System menu Restore transducer connections to electronic control board Replace transducer cable Replace transducer Repl...

Page 36: ...obligation and Buyer s sole and exclusive remedy under the above warranties is limited to repairing using new or reconditioned parts or replacing free of charge except for labor if permanently install...

Page 37: ...35...

Page 38: ...36 Certified ISO 9001 Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 Telephone 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com...

Reviews: