31
5.6
Electric installation
5.6.1
Wiring diagram Condair CP3 D
A1
Temperature
sensor
(0-10V)
F1
Internal
fuse
“Driver
board”
(6.3
A,
slow
acting)
F2
Internal
fuse
“Driver
board”
control
signal
(200
mA,
fast
acting)
F1
Fuse
fan
“Steam
bath
board”
(4
A,
slow
acting)
F2
Fuse
lightning
“Steam
bath
board”
(4
A,
slow
acting)
F3
External
fuse
heating
voltage
supply
F4
External
fuse
control
voltage
supply
H
Remote
operating
and
fault
indication
H1
Control
lamp
steam
bath
On/Off
H2
Control
lamp
lightning
steam
bath
On/Off
H3
Lightning
steam
bath
(24V
AC,
max.
2x
25W)
J
Short
circuited,
if
no
door
switch
is
connected
K1
Main
contactor
(for
connecting
the
heating
voltage
supply
to
the
unit)
M1
Fragrance
pump
(1x230V
AC)
M2
Fan
steam
bath
cabin
(24V
AC,
max.
50W)
M3
Flap
actuator
(alternatively
to
the
fan)
Q3
External
service
switch
heating
voltage
supply
Q4
External
service
switch
control
voltage
supply
S1
Temperature
sensor
(KTY)
S2
Max.
temperature
switch
72
°C
SW1
On/Off
switch
steam
bath
SW2
On/Off
switch
lightning
steam
bath
SW3
Door
switch
steam
bath
(option)
U1
Analogue
output
temperature
0-10V
(=0-100°C)
U2
Analogue
output
temperature
signal
for
the
control
of
the
flap
actuator
M3
X0
Connection
terminal
heating
voltage
X1
Connection
terminal
control
voltage
CPU BOARD
J3 DRIVER B
J2 FAUL
T REMOTE
J1 DRIVER A
J4
CP3 Card Main unit
4
3
2
1
2
1
Analog Out
F1
100mA
Sensor Supply
Max. 60mA
Unit ON
Steam
Service
Error
Fault Remote Board
1
2
3
4
5
6
7
8
9
10
H
Q4
J
F4
L1
N
230 V/1N~/50..60 Hz
+
–
A1
L1
Q3
K1
X0
F3
L1
L2
L3
L1
L2
L3
PE
L1
L2
L3
Heating
400 V/3~/50..60 Hz 230 V/3~/50..60 Hz
Q3
F3
L1
N
PE
230 V/1~/50..60 Hz
F2
200mAF
X2
X7
X4
X3
INLET V.DRAIN V
.CONT
ACTOR
X5
P
N
P1
Modul B
V+
IN
GND
CONT
.SIGN
DRIVER BOARD
J1 CPU BOARD
J4 EXTERNAL CON.
J2 LINK UP
IN
GND
LIM. SIGN
V+
IN
BLOWER
X6
PE
L1
N
SC1
MAIN SUPPL
Y
X1
SC2
LEV
. SENSOR
F1
6.3 A
T
VTX SUPPLY
SWITCH
OUT 24V
OUT 5V
JP3
LinkUp
Termination
JP1
PE
0V
15V
18V
24V
L1
N
rt
bl
rs
gu
F1 4AT
FAN
F2 4AT
LAMP
1
2
3
24V 18V 15V 0V
5
4
3
2
1
4
3
2
1
3
4
2
1
X2
X3
X4
H1
H2
SW2
SW1
M2
STEAM BA
TH
BOARD
SW3
AC 24
V
LA
M
P
FA
N
LIG
HT
GN
D
TE
M
P
SW
ITC
H
TE
M
P
SE
NS
OR
ON
24
V
S2
S1
M1
1
2
3
4
5
6
7
L1
X1
X5
N
L1
N
PE
SC1
SC2
J3
J1
24V
GND
REL2
REL1
LAMP
PUMP
TEMP SWITCH
J2
1
2
3
4
U1
U2
40 °C
AIN
H3
M3
24
V
0V
AI
N
1
2
3
N
PE
PUM
P