3
–
Wochen Timer
:
With the settings in the submenu “Week Timer” you can configure the
week timer for the time controlled operation of the steam generator.
Note: This menu item is available only if the operating mode (see previous
menu item “Operation”) is set to “WeekTime”.
–
Week timer
deactivated
:
–
Week timer
activated
:
If the timer is activated, up to eight switching
points (events 1 - ) can be defined to switch
the steam generator On or Off
.
Each switching point is defined by a weekday
or weekday range, the switching point and
the desired operating status of the steam
generator.
Configuration notes:
– the settings of an event remain active up to the next event.
– the software does not check the plausibility of the timer settings.
Therefore, make sure your settings make sense.
–
Fan
:
With the settings in the submenu “Fan” you can determine the operating
mode of the fan as well as the post-operational time of the fan for drying
the steam bath cabin.
–
Mode
:
Setting the operating mode of the fan.
Factory setting:
3 Stages
Options:
3 Stages
(Operation of the fan with three
performance levels 1/1/2VAC, which are
controlled in dependency of the temperature
in the steam bath cabin)
1 Stage
(Operation of the fan with only one
performance level 2VAC)
Off
(Fan off)
–
Drying time
:
Setting the post-operational time of the fan for
drying the steam bath cabin.
Factory setting:
20 min
Setting range:
1 ... 60 min
Week Timer
Event 1 :18:00
Event 2 :19:00
Event 3 :--:--
Timer :On
Event 4 :--:--
Esc
Set
Event 1
Time :18:00
Steam Bath :On
Weekday :Mo-Fr
Esc
Set
Week Timer
Event 1 :18:00
Event 2 :19:00
Event 3 :--:--
Timer :Off
Event 4 :--:--
Esc
Set
Fan
Drying Time :20min
Mode :3 Stages
Esc
Set