2
. Carefully lift steam cylinder away from the cylinder receptacle, then remove it to the front.
CAUTION!
Put steam cylinder down carefully to avoid damage to the lower connection
piece!
Installation
of the steam cylinder follows the reverse sequence.
Observe the following
:
–
Before installing the steam cylinder in the unit, check the O-ring of the cylinder receptacle for
damage and replace if necessary.
– Moisten the O-ring of the cylinder receptacle with water (do not use grease or oil), then insert
steam cylinder into the receptacle and push it down to the stop.
– Attach the electrode plugs and the level sensor plug to the respective electrode and sensor con-
nections according to the following table.
Steam cylinder type
A363 / D363
A464 / D464
A664 / D664
A674 / D674
Cable configuration
5
Sensor
white
brown
red
black
Sensor
white
brown
red
black
brown
red
black
– Fasten steam hose on the connector in the unit cover and on steam connector of the cylinder
with hose clamps.
CAUTION!
A leaky steam hose can cause damage due to moisture inside the unit.
CAUTION!
The outlet connector of the steam cylinder is made of plastic.
Do not overtighten
the hose clamp on the steam connector of the steam cylinder.