Operating Instructions (GB)
900 191 - V1.0
_________________________________________________________________________________
Page 13
7.3
Operation
TFT display:
Messages are rendered as symbols and plain text via the
colour display, in the selected language.
Operation:
Using a stylus or finger, slight pressure is applied
to the display and the symbols. This is how individual functions
and settings are selected.
Main/load switch:
This switch is used to turn the control system on/off.
See also Chapter 9.4.
Emergency switch – Water infeed:
In case of failure of the control
electronics, the switch can be actuated to manually open (spring-return)
or switch off the valve for the water supply.
In normal operation, the automatic switch position should be
selected.
Mains voltage and a working backup fuse are required.
Emergency switch – Pumping out:
In case of failure of the control
electronics, the switch can be actuated to manually switch the pump(s)
on or off.
In normal operation, the automatic switch position should be
selected!
Mains voltage and a working backup fuse are required.
After changing the parameters/menu settings, it is possible that
the control system initially fails to apply them. Reboot the control
system for the changes to take effect. This means that the supply
voltage and any installed battery module must be switched off
first. After restarting successfully, all parameters are overwritten
with the new data.
Operation as well as the user interface depends on the actual
equipment of the control system. Some functions are only
available after prior activation or with optional hardware.