Page 19
7.8
Pump-out symbols and their meaning
Pump-out symbol:
The symbol changes colour depending on the operating mode, thus indicating the
current status. The “Pump-out” submenu opens when the symbol is pressed.
Colour
Operating mode
Explanation
Ready
Pump-out
Set point level reached. Waiting for request.
Grey
Fault
Pump-out faulty
Circuit breaker has tripped.
Check the relevant pump.
See Chapter 17.0.
Red
Off
Manual pump-out off
The function was manually switched off in the pump-out
menu.
Yellow
Automatic mode
Pump-out switched on
The level has exceeded the set level and the pump-out
function was automatically switched on.
Green
Manual mode
Pump-out manual mode switched on
The function was manually started in the pump-out menu.
Manual operation is limited to 1…120 seconds. The
function is then stopped and switched to automatic mode.
See Chapter 10.2.
Green
Winter operation
Pump-out switched off
The pump shaft is emptied to the set level and the infeed
function is switched off.
See Chapter 12.0.
Blue
7.9
Pump-out operating mode
The submenu shown on the left opens when the symbol is
actuated in the main display.
The operating mode for pumping out can now be changed here.
After actuation and if there are any faults on the pump, the keys
change their colour, among other things.
Manual pump-out off
see also Chapter 7.8
Manual pump-out on
see also Chapter 7.8
Automatic pump-out mode
see also Chapter 7.8
Pump-out fault
see also Chapter 17.0
Pump-out menu
see also Chapter 10.2
Winter operation
see also Chapter 12.0
Pump-out