background image

11 

 

Customize

Select material from pre-defined list via left and right keys. 

 

TCorrect

Temperature correction setup.

 

 

Distance:  

Distance setup

 

 

Humidity: 

Humidity value setup

 

 

TReflect:

  when 

TReflect

  is on, user  can input  the value  of  background 

temperature.  
 

6.4.3.3. Alarm 

 

 

Press 

Menu

 key to activate the main menu. Select 

Setup

->

Analysis setup

 and 

press 

Confirm

  key  to  pop  up  the  Analysis  dialog  box.  User  can  set  temperature 

alarm,  alarm  type,  alarm  color,  isotherm  color,  isotherm  temperature  and 
isotherm  width.  Press 

Up

  and 

Down

  keys to  choose  menu  items, 

Left

  and 

Right

 

keys to modify the item contents. 

Choose 

Alarm type

 as high temp or low temp. Trigger alarm when the Temp 

of object higher or lower than the temp of 

Set Alarm Temp

.  All pixels above this 

temperature  will  change  to  the  color  as  set  in 

Alarm  Color

.    When  the 

Alarm 

Color

 is set to 

None

, only the audible alarm will sound.  When using alarms with 

Area

 measurements, the selected measurement mode, 

Min

Max

 or 

Average

 will 

have to meet or exceed the set temperature in order to trigger the alarm. 

 

Temp  Alarm

  Off

  disables  alarm  function, 

On

  enables  alarm  function 

and allows setting of 

Set Alarm Temp

 and 

Alarm Color

 

Alarm  type: 

set  as  high  temp  .trigger  alarm when  higher  than temp of 

Set Alarm Temp .

set as low temp. trigger alarm when lower than temp 

of 

Set Alarm Temp

 

 

Alarm Color:

 Selects the color in which the alarming pixels are displayed.  

If set to None, no changes are made to the screen’s color. Only enabled 
when 

Temp Alarm

 is set to 

On

 
6.4.3.4.

 

Date/Time  

 

 

 

Allows the user to set the system date  and time.    After  setting, the camera 

will save the current setting. 

Press 

Menu

  key  to  activate  the  main  menu.  Select 

Setup->Date/Time

  and 

press 

Confirm

  key to open the 

Date/Time

  dialog box. User  can set  Year, Month, 

Day, Hour, Minute  and Second. Press 

Up

  and 

Down

  keys to choose menu items, 

Left

 and 

Right

 keys to modify the item contents. 

NOTE:  If  the  imager  is  not  used  for  a  long  period,  the  system  clock  may  need 
reset due to the internal battery being depleted. 

 
 
 

Summary of Contents for IR-CAM4

Page 1: ...easurement 6 4 2 Auto manually 6 4 3 Setup menu 6 4 3 1 Measurement 6 4 3 2 Adjustment 6 4 3 3 Alarm 6 4 3 4 Date Time 6 4 3 5 System setup 6 4 3 6 System Information 6 4 3 7 Factory Default 6 4 4 Fil...

Page 2: ...ry Avoid heating the battery to avoid the risk of explosion Remove the battery from the device if it not used for a long time Do not leave discharged battery in the device 2 FUNCTIONS APPLICATIONS IR...

Page 3: ...imum minimum temp auto tracking Up to1 movable areas maximum minimum and average temperatures Alarm voice color Image control Color palette 6 palettes changeable Image adjustment Auto manual gain and...

Page 4: ...ute button performs 2 functions a The first function is modification of selected parameters It is obtained by a quick press and release less than 2 seconds with this functions to modify their paramete...

Page 5: ...or saving thermal image Press the key once to freeze the image Press Confirm to save the image or Press C to return to real time measurement 5 Menu Confirm key bar Includes Up Down Left Right and Men...

Page 6: ...ement White crosshair 3 Selected spot temperature Yellow crosshair and show by 4 Emissivity Indicates Imagers emissivity setting 5 Minimum temperature Indicates minimum value of the palette 6 Palette...

Page 7: ...t Insert the battery the battery contacts must face into the battery compartment Replace the cover and screw down CAUTION Use only original manufacturer replacement battery Use of incorrect battery ma...

Page 8: ...than 50 charge prior to recharge The ambient temperature for charging should be 32 F 0 C to 104 F 40 C If under 32 F 0 C the battery capacity will be diminished if over 104 F 40 C the battery may over...

Page 9: ...all measurements from the screen Add Hot Spot adds a moving cursor that automatically displays the hottest spot in the image Designated by SH and H Add Cold Spot adds a moving cursor that automatical...

Page 10: ...ialog box User can view or set temperature range lens type temperature unit ambient temperature reference type and reference temperature Press Up and Down keys to choose different items Left and Right...

Page 11: ...rea measurements the selected measurement mode Min Max or Average will have to meet or exceed the set temperature in order to trigger the alarm Temp Alarm Off disables alarm function On enables alarm...

Page 12: ...splay with choices being 20 40 60 80 and 100 Trigger User can define the trigger key function from Spot Temp Area Temp and Save key Spot Temp Adds or deletes Spot Measurement Area Temp Adds or deletes...

Page 13: ...lete all parameters defined by user NOTE Restoring Default settings will NOT delete images stored on the TF card 6 4 4 File 6 4 4 1 Open Press Menu key to activate the main menu Select File Open press...

Page 14: ...will prompt the user to install a TF card The Display will acknowledge when the TF card is installed properly 6 4 4 3 Auto Save Auto Save allows the camera to automatically save images at a user spec...

Page 15: ...nds the power on routine will finish and the camera will start its measurements Remove the lens cap and aim at the target Adjust the focus for the clearest target thermal image NOTE Failure to properl...

Page 16: ...e to save the image or select Cancel to exit the operation Press Menu key to activate the main menu Choose File Save and the system will initiate the save cycle With the Trigger parameter located in S...

Page 17: ...this type of damage of microbolometer detector The actual temperature of the object may differ from the measurement result of the device The examined surfaces may be potentially dangerous Measured obj...

Page 18: ...aterial or workmanship in full volume and at its own expense 2 The warranty period is 24 months and starts from the date of purchase by the end consumer see the original supporting document 3 The Warr...

Page 19: ...95 Candle soot 20 0 95 Rough lead surface 20 0 98 Oil paint Value of 16 colors 100 0 94 Paper White 20 0 93 Sand soil Surface 20 0 90 Timber Dressed 20 0 90 Water Distilled water 20 0 96 Skin Human 3...

Page 20: ...20...

Reviews: